ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 111
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
NAME
Access
(R/W)
Possible value on the
serial port of the unit
Comments
Module
ALARM.INPUT_FAULT
R
"ON" or "OFF"
Indicates if there is an alarm on an input seta as FAULT
ECU |
DRVn
ALARM.INPUTSWITCH
R
"ON" or "OFF"
Indicates if the current audio input corresponds to the
highest priority channel
ECU |
DRVn
ALARM.INT_TEMP
R
"ON" or "OFF"
ON => indicates the temperature of the internal sensor
is higher than the max threshold
ECU |
DRVn
ALARM.LINE1
R
"ON" or "OFF"
ON => no signal on the input LINE1
ECU |
DRVn
ALARM.LINE2
R
"ON" or "OFF"
ON => no signal on the input LINE2
ECU |
DRVn
ALARM.LIST
R
Returns the list of current alarms in ASCII format
ECU
ALARM.LOAD1
R
"ON" or "OFF"
Indicates the max temperature of load1 is higher than
the threshold, or that there is no communication
ECU
ALARM.LOAD2
R
"ON" or "OFF"
ON => indicates the max temperature of load2 is
higher than the threshold, or that there is no
communication
ECU
ALARM.LOGGING
R
"ON" or "OFF"
ON => two consecutive failed attempts to write on the
µSD card
ECU
ALARM.MPX1
R
"ON" or "OFF"
ON => no signal on the input MPX1
ECU |
DRVn
ALARM.MPX2
R
"ON" or "OFF"
ON => no signal on the input MPX2
ECU |
DRVn
ALARM.MPX3
R
"ON" or "OFF"
ON => no signal on the input MPX3
ECU |
DRVn
ALARM.MPX4
R
"ON" or "OFF"
ON => no signal on the input MPX4
ECU |
DRVn
ALARM.OVDR
R
"ON" or "OFF"
Indicates whether the input power is too high (ON) or
not (OFF)
PAn
ALARM.OVDRTRIP
R
"ON" or "OFF"
Indicates the overdrive counter has maxed out
PAn
ALARM.PA
R
"ON" or "OFF"
Indicates amplifier is in warning or fault
ECU
ALARM.PIN
R
"ON" or "OFF"
Indicates that the input power is too low
DRVn |
PAn
ALARM.PINWARN
R
"ON" or "OFF"
Indicates that the input power is below low threshold
PAn
ALARM.PLAYER
R
"ON" or "OFF"
ON => no signal on the generator
ECU |
DRVn
ALARM.PLL
R
"ON" or "OFF"
Indicates whether the PLL is locked (OFF) or unlocked
(ON)
ECU |
DRVn
ALARM.PREFTRIP
R
"ON" or "OFF"
Indicates the reflected power counter has maxed out
PAn
ALARM.PRESSURE
R
"ON" or "OFF"
ON => indicates the pressure of the internal sensor is
lower than the min threshold
ECU |
DRVn
ALARM.PSU
R
"ON" or "OFF"
Indicates PSU is in warning or fault
ECU
ALARM.PSU_TEMP
R
"ON" or "OFF"
ON => PSU alarm on, OFF=> no alarm
DRVn
ALARM.RDSSWITCH
R
"ON" or "OFF"
Indicates there was a RDS switch (auto mode only)
ECU |
DRVn
ALARM.RELAY
R
"ON" or "OFF"
On if RF switch in fault
ECU
ALARM.RESERVE
R
"ON" or "OFF"
On if reserve drive is unavailable
ECU
ALARM.SFM
R
"ON" or "OFF"
Indicates a SmartFM malfunction
ECU
ALARM.SFN
R
"ON" or "OFF"
When SFN is enabled, indicates a loss of the external
10 MHz or a loss of the external 1 PPS or a difference
between the set SFN delay and the measured SFN
delay. This alarm indicates a loss of SFN, not a loss of
transmission.
ECU |
DRVn
ALARM.SUPPLY1
R
"ON" or "OFF"
Indicates PSU is in warning or fault
DRVn |
PAn
ALARM.SUPPLYTRIP
R
"ON" or "OFF"
Indicates the PSU trip counter has maxed out
PAn