10.3.4.
Remote monitoring function pinout (relays)
Event
Remote Monitoring
Output name
Common
LOCAL
RM1
REL1_RT(1)
REL1_C(14)
FAULT
RM2
REL2_RT(2)
REL2_C(15)
WARNING
RM3
REL3_RT(3)
REL3_C(16)
RF ON ou SWITCHOVER
ou RESERVE OK+
RM4
REL4_RT(4)
REL4_C(17)
ON ou PRESELECT 1+
RM5
REL5_T(18)
REL5_C(6)
OFF ou PRESELECT 2+
RM6
REL5_R(5)
REL5_C(6)
VSWR
RM7
REL6_RT(19)
REL6_C(7)
Numbers in parenthesis indicated the pin number on the DB25 connector.
+ Default configuration for ACU
A closed link indicates valid information when configuration is as in the following table.
Default jumper position:
Relay
Positions
Contacts
REL_1RT
JUMP2[1 ;2]
NO
REL2_RT
JUMP3[1 ;2]
NO
REL3_RT
JUMP5[1 ;2]
NO
REL4_RT
JUMP1[1 ;2]
NO
REL6_RT
JUMP4[1 ;2]
NO
Jumpers from 1 to 5 (JUMP1 to JUMP5): select the NO or NC contact of the relays.
Switching to local mode (relay 1) prevents remote control: it therefore disables all other relays and commands.
All jumpers are normally open on the analog GPIO board.