The Micro-Link keypad operates much like the larger Opti-Link 

keypad. The major difference is that there is only one large key, 

performing 3 functions instead of separate Pursuit, Arrival and 
Reset keys. The associated Interface/Output Receiver has 6 high 
current output stages for controlling external equipment. 

Introduction

Installation Requirements and System Limitations

The Micro-Link System is designed for 12-volt operation only. 
The Interface Output/Receiver unit

 must 

be mounted in 

a well ventilated dry location and away from heat sources, 
preferably on a metal surface to conduct heat away. 

UNDER NO 

CIRCUMSTANCES SHOULD THE UNIT BE MOUNTED INTO 

AN ENCLOSED SPACE WHICH WOULD ALLOW HEAT TO 

BUILD UP 

Maximum output per relay – 5 Amps. 
Maximum total output – 15 Amps 
 

EACH OUTPUT MUST BE FUSED APPROPRIATELY FOR THE 

LOAD CONNECTED TO IT. 

Pursuit / Arrival / Reset 

External ‘999’ Input 

Walk Test

Sleep / Wake-up / Sleep Test

Audio / Visual Warnings

Low Light Keypad Dimming

Operation

In normal operation the large key, SW7, functions as a reset 
switch. If no channels are selected, pressing SW7 will cycle 

between a pre-defined Pursuit Setting, an Arrival setting and 
finally a Reset. When in Pursuit mode the key will light blue. 

When in Arrival mode the key will light red. 

Connecting pin 4 on the keypad connector to +12V via an 
external momentary switching source will enable the Pursuit 
setting on the keypad. 

Pressing and holding the large button, SW7, when not in either 
Pursuit or Arrival mode initiate a walk test. Each channel will then 
be lit individually for a few seconds allowing a test of all outputs.

The unit will automatically go to sleep after an hour if no 
channels are selected and the supply voltage is less than 13.5 
volts (i.e. the engine is not running). 

The unit will wake-up when a key is pressed or when the supply 
voltage exceeds 13.5 volts.  
 
For test purposes the unit can be put to sleep by pressing and 
holding SW6 and SW7 for a few seconds. 

As a channel on reminder, the warning LED will flash and the 

unit will beep every 30 seconds whenever a channel is on. The 

warning LED will flash continuously when the battery voltage falls 

below a critical level 9.5volts.  
 
Finally the LED will light continuously when the programming 
lockout is disabled. 

When the ambient light level falls below a pre-set level the 
keypad illumination will automatically dim. This is controlled by 

the LDR (light dependent resistor) adjacent to SW1. 

DO NOT 

COVER THIS DEVICE. 

LDR 

Warning Led 

SW1 

SW2 

SW4 

SW5 

SW3 

SW6 

SW7 

Keypad Layout

Содержание Micro-Link ZE0187

Страница 1: ...dway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com IN STALLATION GUIDE Micro L...

Страница 2: ...s CAUTION Modules and connectors are not waterproof Install modules and cables in a dry location away from excessive heat humidity and any components likely to damage the system It is the installers r...

Страница 3: ...pment supply Grey I Data Output to an additional nterface Unit Dip switch 1 in the ON position enables the additional unit Grey 12Vdc Fused 25A 0v DIP SWITCHES BOTH SWITCHES SHOULD BE SET TO THE OFF P...

Страница 4: ...re selected pressing SW7 will cycle between a pre defined Pursuit Setting an Arrival setting and finally a Reset When in Pursuit mode the key will light blue When in Arrival mode the key will light re...

Страница 5: ...nds until the blue Pursuit or red Arrival start to flash The leds will flash for 30 seconds in which time the required channels can be switched on off After this time the unit will store the new setti...

Страница 6: ...oodway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 6 Note...

Страница 7: ...oodway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 7 Note...

Страница 8: ...ring Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com Made in the UK ISO 9001 2015 Certified...

Отзывы: