background image

Woodway Engineering Ltd 

Lower Road, Barnacle

Coventry, CV7 9LD

United Kingdom

Tel:  +44 (0) 24  76 841750 

Fax:  +44 (0) 24  76 621796

[email protected]

www.woodwayengineering.com

I N S T A L L A T I O N   G U I D E

5

Programming

Reprogramming and the Programming Lockout

Programming Pursuit / Arrival Settings 

Programming Strobe Functionality 

Programming Momentary Action 

Global Reset

Before the unit can be programmed, the programming lockout 
must be disabled. Pressing and holding all the switches except 
channel 5 will deactivate the programming lockout for 5 minutes. 
Whilst the programming lockout is disabled the warning LED will 
remain continuously lit. If power is removed, or the unit is put to 
sleep the unit will return to the locked mode. 

Disable the programming lockout as described above.

When in Pursuit or Arrival mode, pressing and holding the large key, SW7, will allow programming of each mode. The key must be 

held for a number of seconds until the blue (Pursuit) or red (Arrival) start to flash. The leds will flash for 30 seconds in which time 
the required channels can be switched on/off. After this time the unit will store the new settings. Programming can be cancelled by 

pressing the large button again once (reset). 

The buttons SW1, SW2 and SW3 can be made self-cancelling in two different ways. 

•  Self Cancelling 

- Only one button can be active at one time. 

Pressing and holding the large button, SW7 and SW1 will enable/disable the self-cancelling mode.

•  Special Setting

 - Operating SW1 only also activates/deactivates SW2 and SW3. 

Pressing and holding the large button SW7 and SW2 will enable/disable the special setting.

Any button can be made momentary. This is achieved by pressing and holding SW7 and SW4 until the large button will flash blue 

and red. This indicates that the unit is in momentary programming mode. Any channel can now be activated. After 30 seconds, any 
channel lit will become momentary. 

If the programming needs to be un-done, the unit can be returned to the factory default setup by pressing and holding SW7 and SW3 
for 5 seconds. 

Key held 

Key not held 

Содержание Micro-Link ZE0187

Страница 1: ...dway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com IN STALLATION GUIDE Micro L...

Страница 2: ...s CAUTION Modules and connectors are not waterproof Install modules and cables in a dry location away from excessive heat humidity and any components likely to damage the system It is the installers r...

Страница 3: ...pment supply Grey I Data Output to an additional nterface Unit Dip switch 1 in the ON position enables the additional unit Grey 12Vdc Fused 25A 0v DIP SWITCHES BOTH SWITCHES SHOULD BE SET TO THE OFF P...

Страница 4: ...re selected pressing SW7 will cycle between a pre defined Pursuit Setting an Arrival setting and finally a Reset When in Pursuit mode the key will light blue When in Arrival mode the key will light re...

Страница 5: ...nds until the blue Pursuit or red Arrival start to flash The leds will flash for 30 seconds in which time the required channels can be switched on off After this time the unit will store the new setti...

Страница 6: ...oodway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 6 Note...

Страница 7: ...oodway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 7 Note...

Страница 8: ...ring Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com Made in the UK ISO 9001 2015 Certified...

Отзывы: