I N S T A L L A T I O N G U I D E
3
System Connection Diagrams
SW
4
SW
1
SW
5
SW
2
SW
6
SW
3
SW
7
SK
1
Grey
Externa
l ‘999’ Input +12V Momentary
Data Output to Interface Unit
0v
+12Vdc
Black
Red
Yellow
Data Input from Keypad
1
1
8
6 7
Pin 8 is a permanent UNFUSED
output. This pin is for test
purposes only and is not
intended to be used for
equipment supply.
Grey
I
Data Output to an additional
nterface Unit (Dip switch 1 in
the ON position enables the
additional unit)
Grey
+12Vdc Fused @ 25A
0v
DIP SWITCHES
BOTH SWITCHES SHOULD BE
SET TO THE OFF POSITION
Black
Red
Per12V 5A output when
system is in ‘Wake Up’ mode.
No output when in ‘Sleep Mode’.
See 4.3
Use to supply Auxiliary equipment.
Outputs 1
–
6.
O12V. Use to control
external equipment.
Maximum Load 5A per outlet.
Maximum Total Load 15A
Each output must be fused
appropriately for the load
connected to it.
Micro-Link Keypad
ZE0187
MicroLink Relay I/F
ZE0210
Dimensions:
103 x 52 x 25
The Micro-Link keypad draws 82.5mA @13.8V when all switches are illuminated and 7.2mA @13.3V
when asleep.