Woodway LokoStation PPS Скачать руководство пользователя страница 15

14

Resets all values in the display segments back to zero. Press this button when the data display module still shows 
previous values, e.g. from the previous user.

Then operate the treadmill via the handrail-mounted keypad or an external control system. 

e)  Speed display (10) 

The upper display (10) shows the current treadmill speed. Your system can be set to display either kilometers per 
hour or meters per second via button (11) located to the right of this display. The two LEDs located between the 
display and the button indicate which of the two unit systems is active at any given time. The display includes a 
leading sign. This lights up when the “reverse switch” function is activated (reversal of the direction of travel of the 
slat-belt running surface to enable downhill operation).  This function is not supplied as standard equipment and 
can only be activated by means of an external control system via the RS-232 interface.

f) 

Distance and energy display (9) 

This display element (9) shows, updated at ten-second intervals, the total distance traveled in kilometers and the 
total energy expended by the runner in kilocalories since the last time the treadmill was started. The upper LED 
next to the display indicates that the displayed value corresponds to the distance. The lower one indicates display 
of energy exerted.
The values of distance and energy remain in the system after the treadmill has been stopped. To delete them, 
press the reset button (8).

g)  Elapsed time display (7) 

The display element (7) shows the elapsed training/therapy time. In the beginning, the display shows the time 
elapsed since the start of the session, with the minutes on the left side and the seconds on the right. The two 
values are separated by two dots that blink once per second. The upper LED to the right of the display indicates 
this condition.
When the length of a training session exceeds one hour, the display changes to hours and minutes. At that point, 
the upper LED turns off and the one beneath it lights up instead.

The values remain in the system after the treadmill has been stopped. To delete them, press the reset button (8).

h)  Inclination and pulse rate display (6) 

These two values are likewise shown on a single display field (6). 

If the Polar transmission chest strap is used, the pulse rate in beats per minute (bpm) is displayed. 

Caution – Possible danger of injury or damage.  

Although the Polar pulse rate measurement provides very precise data, the pulse measurement 
system is only used as a general indicator. The treadmill pulse measurement is not intended for 
diagnostic or medical purposes. For diagnostic or medical purposes, use only ECG instruments 
specifically designed and approved for that purpose. 

Following modification of the degree of inclination in % (via the handrail-mounted keypad or an external control 
system), the new value appears on the display for five seconds. The upper LED next to the display is lit. If the 
inclination remains unchanged, the runner’s current pulse rate will be displayed after this period of time and the 
lower LED will be lit.

As with the speed value, the inclination display also has a leading sign. Negative inclination is only possible for 
treadmills that are equipped accordingly. The leading sign lights up when the “reverse switch” function is activated 
(reversal of the direction of travel of the slat-belt running surface to enable downhill operation).  This function is 
not supplied as standard equipment and can only be activated by means of an external control system via the RS-
232 interface.

For treadmills with no pulse rate monitor system or when the transmission chest strap is not worn, the degree of 
inclination is displayed continuously. 

Содержание LokoStation PPS

Страница 1: ...Operating Instruction LokoStation WOODWAY GmbH Steinackerstr 20 79576 Weil am Rhein Germany Phone 49 0 7621 940 999 0 Internet www woodway de Fax 49 0 7621 940 999 40 e mail info woodway de Rev 01 06...

Страница 2: ...and up to date as possible Insofar as legal limits allow we reject any liability for damages resulting from use of this operation manual At most we accept liability for intent and culpable negligence...

Страница 3: ...the handrail mounted keypad 13 6 3 WOODWAY User System WUS 15 6 3 1 Switching the treadmill ON 15 6 2 3 Manual Use of the Handrail mounted keypad 18 6 2 4 Start Program 19 6 2 5 Edit Program 21 6 2 6...

Страница 4: ...he values listed on the nameplate of the slat belt treadmill Any modification of the input voltage should be performed only by WOODWAY or by their duly authorized service agent The treadmill must be c...

Страница 5: ...ust be performed only by the manufacturer or their duly authorized service agents never by the operator We are not liable for damages resulting from unauthorized service or from improper maintenance p...

Страница 6: ...and it will also protect the floor covering from undue wear Due to the weight of the LokoStation with treadmill ca 1 764lbs the ceiling or the floor should have the necessary support capability or th...

Страница 7: ...position it underneath the treadmill and then move the treadmill to the desired new location If the treadmill must be disassembled the panels and rails can be removed for ease of transportation refer...

Страница 8: ...on and designations 1 Emergency Stop pull wire magnet 2 Handrail mounted keypad 3 Lifting bar insertion into the hole for which it was designed 4 RS 232 USB interface 5 ON OFF main power switch Power...

Страница 9: ...tion 2 One Arm Construction 3 Body Static Dynamic Body Weight Support 4 Rope Length Adjustment Variations possible 5 Central Winch Static Mode 6 Crank Dynamic Body Weight Support 7 Security Spikes for...

Страница 10: ...tion of the Hips x x x x Dynamic Static Body Weight Support x x x x Symmetric Asymmetric Body Weight Support x x x x Variable Deviation Points x x x x Wheel Chair Ramp incl Handrail left x x x x 2 adj...

Страница 11: ...n against electrical shock equipment for external and internal use on patients however not for direct use on the heart Protective conductor connection grounded for DIN 40011 Attention Before working o...

Страница 12: ...area the 230 V power supply is interrupted and an Emergency Stop is initiated The magnet must be positioned on the red field with the yellow ring When the magnet is not correctly positioned the tread...

Страница 13: ...of the Emergency Stop systems 6 2 Data Monitor The WOODWAY data display module is used to show the treadmill s current control parameters and modes In addition the Standby Button and the Emergency Sto...

Страница 14: ...down press the blue button Speed will diminish gradually You can either press this button several times in succession or hold it down continuously until the desired speed has been reached To stop more...

Страница 15: ...ink once per second The upper LED to the right of the display indicates this condition When the length of a training session exceeds one hour the display changes to hours and minutes At that point the...

Страница 16: ...rol panel In addition the treadmill can also be operated i e via speed and inclination settings from the keypad on the handrail 1 Touch screen 2 Standby button 3 Emergency Stop pull wire magnet 4 Cont...

Страница 17: ...red up the treadmill with the main ON OFF switch located under the right side as viewed from the running direction activate the treadmill by pressing the Standby button 2 To stop the treadmill please...

Страница 18: ...n hh mm ss x Heart rate in bpm beats per minute If the Polar transmission chest strap is used the pulse rate in beats per minute bpm is displayed Caution Possible danger of injury or damage Although t...

Страница 19: ...l operation mode the direction of travel automatically resets to forward a Inclination adjustment To activate the inclination for running uphill or downhill the latter being an optional feature press...

Страница 20: ...or up and down for marking the desired program Program names are displayed together with indicators showing whether they are package or custom programs SELECT loads the program of your choice i e the...

Страница 21: ...for diagnostic or medical purposes For diagnostic or medical purposes use only ECG instruments specifically designed and approved for that purpose x Power in watts or energy value in kcal To select di...

Страница 22: ...the button EDIT PROGRAM The next screen then allows you to select the following operations SELECT PROGRAM This switches you to the Treadmill programs menu where you can select a treadmill program as...

Страница 23: ...le shown above press the button four more times until the display shows Step 5 of 21 SPEED etc Select the parameter that you would like to change Modify the given parameter by entering the new value C...

Страница 24: ...s that you have modified DELETE deletes the currently displayed program step INSERT inserts a new program step You must enter the parameters for this program step separately as described above CANCEL...

Страница 25: ...llowing mask Press the SAVE button only at the very end after you have completed all entries In the following mask you will be asked to confirm that you really want to save the program SAVE stores the...

Страница 26: ...e pulse measurement system is only used as a general indicator The treadmill pulse measurement is not intended for diagnostic or medical purposes For diagnostic or medical purposes use only ECG instru...

Страница 27: ...SE SETPOINT Use the number keypad on the touch screen to enter this value see above LIMIT SETTINGS This allows you to enter limits for speed and inclination The treadmill generally adjusts itself to a...

Страница 28: ...llowing screen appears Press the corresponding button to adjust the desired value The programmed value is displayed in this mask e g speed in km h Press the END button to confirm acceptance of the new...

Страница 29: ...erformance parameters of the treadmill The contents of this display screen are only for your information these parameters cannot be modified Press the Arrow button to access further technical informat...

Страница 30: ...f the Bar Rail are adjustable Gas Pressure Blocking Springs which allow combined with an easy to use clamping fixture for locking the Bar a uniquely simple handling Figure 1 Push button for locking th...

Страница 31: ...sired height This can be done in both directions up down The Rail moves up almost automatically light pull is needed downwards the Rail has to be pushed against the resistance of the Gas Spring Fig 2...

Страница 32: ...e COG throughout the whole gait In every single phase of patient movement it is guaranteed that the chosen weight supports the patient As a precaution check the patient s ability to stand alone before...

Страница 33: ...e the following tool for adjusting the shoulder width Figure 3 Setting the Deviation Points Take the adjustable knob shown in the picture pull it down for release and shift it to the left or right sid...

Страница 34: ...spikes should be pushed in and visible over the weight change plates As a result dynamic weight support will be prevented Figure 5 Central Winch The elevation ropes will be pulled up by turning the ce...

Страница 35: ...counter clockwise direction At this point the Weight Support System is in the static position i e the security spikes are pushed in Figure 6 Setting the Dynamic Body Weight Support With the crank one...

Страница 36: ...inside the drive link sink to the lowest position As a result one can reset the security spikes and the weight support system is back in the static weight position 6 5 4 Rope Length Adjustment The rop...

Страница 37: ...aching the patient the 2 carabiners should be brought to a middle position default position see figures A B A B Pulling down the rope adjustment will lift up the left body half of the patient see figu...

Страница 38: ...By loosen the rope adjustment the left body half will be lowered see figure E F E F To guarantee a safe fixation of the rope the a self locking rope By pulling the rope it gets automatically fixed...

Страница 39: ...d off and the main power cable must be unplugged 7 2 Treadmills in the Medical Market Weekly x Wipe the handrails control panel and exterior panels with a damp cloth x Check the power cable for cracks...

Страница 40: ...we have provided in the service kit The Prescribed Recurring Test Period The prescribed recurring test period according to BGV A4 VBG 4 Accident prevention directive averages for treadmills 4 years re...

Страница 41: ...ion x All security relevant screws Every six 6 Months x Examine the T Tracks Every twelve 12 Months x Exchange replace all ropes x Exchange replace all pulleys x Examine the entire system for potentia...

Страница 42: ...he following points x Is the treadmill switched on main switch x Is the treadmill properly connected to an electrical socket power cable correctly inserted into the treadmill and the electrical socket...

Отзывы: