Safety & General Information
Noise Level
1
1-18
HDSdoc021716
Safety & General Information
DANGER!
It is recommended that a 30mA Ground Fault Interrupter (GFI) be
used.
1.11 Noise Level
See Table 1-8.
The average noise level is given in the table below
12
.
1.12 Overall Dimensions
See Table 1-9.
The overall dimensions of the LT70 sawmills with M frame are listed below.
3-Phase
Volts
Fused
Disconnect
Switch
Recommended
Wire Size
15kW
(EA20)
400 VAC
32 A
6 mm
2
up to 15 m of length
18,5kW
(EA25)
400 VAC
40 A
6 mm
2
up to 15 m of length
Hydraulic
(+4kW)
400 VAC
+10A
+1,5 mm
2
up to 15 m of length
TABELA 1-0
Sawmill
Noise Level L
EX8
LT70 E15 AH
83,0 dB (A)
LT70 E20 AH
83,0 dB (A)
LT70 D42 DH
87,4 dB (A)
TABELA 1-8
1. The noise level measurement was taken in accordance with PN-EN ISO 3746 Standard. The noise
exposure level given above concerns an 8-hour work day. Value for associated uncertainty K=4dB.
2.The measured values refer to emission levels, not necessarily to noise levels in the workplace. Although
there is a relation between emission levels and exposure levels, it is not possible to determine with certainty
if preventives are needed or are not needed. The factors affecting a current level of noise exposure during
work are inter alia room characteristics and characteristics of other noise sources, e.g. number of machines
and machining operations nearby. Also, the permissible exposure level value may vary depending on
country. This information enables the machine’s user to better identify hazards and a risk.
Sawmill Model Length
1
Width
2
Width
(Operating Position
with Loading Arms)
Height
3
Weight
Weight
w/Trailer
TABLE - 0-0
Содержание LT70M AH Super