PG
8
OF
24
M0183.06 AUGUST 2019
Whatcom Gas-Fired Vertical Rotisserie CE
Installation and Operation Manual
INSTALLATION CLEARANCES
This appliance is not intended to be fixed to an installation wall.
WARNING:
Do not pack required clearance spaces with insulation or other material�
FRONT
All obstructions in lighter shaded
area must be removable for service
access:
914mm
(3') from sides and
back, and
914mm
(3') above�
Leave area within dotted lines open (3') to
allow allow or door swing and user access�
With optional Double Door models, the same
access (3') is also required�
Darker shaded
areas indicate
min� clearance
to
combustible
materials�
Min� clearance to
non-combustible
materials = 0"
152
mm
152
mm
SERVICE ACCESS
Countertop models
must allow access all the way around
and above unit as shown below�
Caster units
must be able to roll completely free from
obstructions to allow access as shown below�
304mm
- DD
152mm
CLEARANCES
FRONT
•
Allow
36"
to allow for door swing and user access�
SIDES
• Minimum clearance from sides of rotisserie to
combustible
construction is
152mm
(6")�
•
Minimum clearance from sides of rotisserie to
non-combustible
construction is
0"
.
BACK
• Minimum clearance from back of rotisserie to
combustible
construction is
152mm
(6")�
•
Minimum clearance from back of rotisserie to
non-combustible
construction is
0"
.
FLOOR
•
Installation on
non-combustible
floors only�
OPTIONAL REAR DOOR MODELS - BACK
(model number includes “-DD”)
• Minimum clearance from back of rotisserie to
combustible
construction is
304mm
(12")�
•
Minimum clearance from back of rotisserie to
non-combustible
construction is
0"
.
•
However, allow
914"
(36") at rear to allow for door
swing and user access�