INTRODUCTION
Machine description
INTRODUCTION
doc121819
1-5
1
CHIP EXTRACTOR
MP160 planer/moulder must be connected to chip extractor with a capacity of at least 3 000m
3
/h.
Remember that chip container has to be equipped with an air vent (e.g. a fine net or filter if dust are
collected indoors). Poor suction is often due to poor airflow from the chip container. During work in
heated rooms, it is necessary to remember that the fan will quickly cool the space if the filtered air will not
be supplied back into the building. The fire risk and dust emissions (discharge) must be considered
because of chip collection.
WARNING!
Because of chip collection there is fire risk and dust
emission.
Contact the local authorities for advice in designing a chip collection system to conform with national
rules.
It is necessary to set the fan so that will be easy to reach the switch.
IMPORTANT!
Remove the chips from the planer/moulder when the
work is finished.
CHIP EXTRACTOR TECHNICAL REQUIREMENTS
1
The chip extractor must be approved according to the CE-standard.
The airflow "without external connection" must be approx. 1500 m3/hour.
(The manufacturer's standard indication of airflow.)
The chip extractor hose diameters for the planer/moulder = 100 mm (4”) x 1 .
Pressure drop in the planer/moulder is 26 mm column of water at 25 m/s.
Dust extractor airflow should be 1500 m
3
/h, pressure drop should not exceed 1,5kPa.
IMPORTANT!
The dust extractor hoses must be grounded or made
with materials not accumulating electrostatic charge.
CAUTION!
Always turn on the chip extractor before starting the
machine
1. EN 12779:2016-04 standard contains requirements for chip and dust extraction systems equipment with
fixed installations.
!
!