MF130 SPECIFICATIONS
Specifications of the moulder
MF130 SPECIFICATIONS
doc101521
6-2
6
See table 6-1.
Weight of the MF130 moulder are given in the table below.
6.2
Specifications of the moulder
See table 6-2.
Wood-Mizer MF130 moulder nomenclature is given in the table below.
See table 6-3.
See the table below for specifications of the MF130 moulder motors.
See table 6-4.
The noise level generated by Wood-Mizer MF130 is given in the table below
1
2
3
IMPORTANT!
The total value of hand-arm vibration the operator may
moulder type
MF130
Weight
675 kg
Weight with transport box
740 kg
TABLE 6-1
Volts
MF130EA3S
1 ph 230V CE
MF130EB3S
3 ph 230V CE
MF130EH3S
3 ph 400V CE
TABLE 6-2
MF130EA3S
MF130EB3S
MF130EH3S
Motor Type
Electric Motor
Electric Motor
Electric Motor
Rated Voltage
1x230V
3x230V
3x400V
Rated revolutions
2900r.p.m.
2900r.p.m.
2900r.p.m.
Rated power
2.7 kW
3 kW
3 kW
Wood-Mizer Part No.
533651
Max. Current
16 A
10.8 A
5.8 A
TABLE 6-3
Noise Level
moulder MF130
Equipped with electric motor
L
wA
= 104,2 dB (A)
TABLE 6-4
1. The noise level measurement was taken in accordance with PN-EN ISO 3746 Standard . Value for
associated uncertainty K=4dB.
2. The measured values refer to emission levels, not necessarily to noise levels in the workplace. Although
there is a relation between emission levels and exposure levels, it is not possible to determine with certainty if
preventives are needed or are not needed. Factors that influence the actual level of exposure of the workforce
include the characteristics of the work room and the other sources of noise etc. i.e. the number of machines
and other adjacent processes. Also, the permissible exposure level value may vary depending on country. This
information enables the machine’s user to better identify hazards and a risk.
!