OPERATION
Pre-Operation Check
EGdoc121421
4-1
4
SECTION 4 OPERATION
4.1
Pre-Operation Check
IMPORTANT!
Before starting to use the MF130 Moulder you have to
meet the following conditions:
Set up the MF130 Moulder on firm, level ground and level the machine. Secure the machine
to the ground to prevent moving during operation. A cement pad with 8-10 mm diameter
anchor bolts is recommended.
The MF130 Moulder can be operated indoors with the sawdust collection system only.
The MF130 Moulder must not be operated when it is raining/snowing and in case of rain or
snow the machine must be stored under roof or indoors.
The MF130 Moulder can be operated in temperatures ranging from -15
o
C to +40
o
C only.
The illuminance at the operator's position should be at least 300 lx
1
.
The operator’s position and E-Stop button location are shown below.
See Figure 4-1.
See table 4-1.
Have a qualified electrician install the power supply (according to EN 60204
1. The light source must not cause the stroboscopic effect.
FIG. 4-1
!
E-STOP