OPERATION
Pre-Operation Check
4
4-2
EGdoc121421
Standard). The power supply must meet the specifications given below.
IMPORTANT!
It is recommended that a 30mA GFI (Ground Fault
Interrupter) be used.
IMPORTANT!
When starting the machine for the first time, check that
the main motor rotation.If the rotation direction is incorrect, invert the
phases in the phase inverter in the power socket (electrical box).
Setting the phases in the phase inverter correctly will ensure correct
rotation directions of the main motor and the blade.
WARNING!
If the drive belt breaks, wait until all rotating parts are
completely stopped. Failure to do so may result in serious injury or
death.
Check if no tools have been left in the machine.
Check if the cutter can rotate freely.
Review the safety instructions!
Make sure the emergency stop button is released.
Make sure the side cover is closed. Be sure all the parts of the machine are tightened, especially
the cover of the working element.
Make sure that no one apart from the operator is in the high risk area.
Turn on the chip extractor.
DANGER!
Connect the Moulder electrical installation. Check the
rotational direction.
3-Phase
Volts
Fused Disconnect
Switch
Suggested Wire Size
400 VAC
16 A
1.5 mm
2
Max. length: 15 m
TABLE 4-1
!
!