![Wood-mizer LT70AC Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/wood-mizer/lt70ac/lt70ac_safety-setup-operation-and-maintenance-manual_994657017.webp)
SETUP
Site Preparation
SETUP
doc100206
3-1
3
SECTION 3 SETUP
3.1
Site Preparation
IMPORTANT!
This information is provided so that you may
have your site prepared for installation of your electric
sawmill. In order to properly install your sawmill, you need
to:
1. Prepare a firm, level area where the sawmill can be anchored.
There should be
enough room around the sawmill for operators, sawdust removal, log loading and board
removal. A cement pad with 1/2” diameter anchor bolts is recommended. The cement pad
should be rated to support 6350 lbs./sq.ft. at each sawmill foot position.
The design of your site layout should be determined at the time of purchase.
The sawmill is designed for indoor operation and should be fully protected from outdoor
elements.
2. Have a qualified electrician install the power supply before receipt of your sawmill.
The power supply should be installed as close to the machine as possible and must meet
the enclosed specifications concerning wire size, fused disconnect, and voltage.
The electrical installation must also meet local codes.
See Table 3-1.
Power Supply Specifications for LT70 Remote Sawmills
3. Have a qualified electrician present when the sawmill is to be installed.
All relevant
motor specifications and wiring information is provided. When scheduling an electrician
for the day of installation, please confirm that they have enough of the proper size cable
(wiring), as shown above. Many electricians may not stock this cable, which could
seriously delay installation and training.
3-Phase
Volts
Fuse
Disconnect
Time
Delay
Fuse
Suggested Wire
Size
400 VAC
100 Amps
63 Amps
10 mm
2
up to 15 m long
TABLE 3-1
!