![Wood-mizer A/DH5 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/wood-mizer/a-dh5/a-dh5_safety-setup-operation-and-maintenance-manual_994631095.webp)
Troubleshooting Guide
Electrical Problems
Troubleshooting Guide
doc111517
4-3
4
4.2
Electrical Problems
PROBLEM
CAUSE
SOLUTION
Up/down Excessively Slow.
Vertical wear pads too tight.
Adjust pads.
Up/down belt loose.
Adjust belt to be as loose as possible
without slipping
Up/down Or Power Feed
Motors Do Not Work.
Worn/dirty contacts in drum switch.
Replace switch or remove control panel
cover and clean contacts.
Bad key switch.
Replace key switch.
Circuit breaker.
Burned-out motor.
Replace motor.
Bad connection on battery post or
loose wire.
Check for loose wire or terminal
connections.
Up/down motor relay damaged.
Have a qualified electrician replace the
relay.
Up/down motor is damaged.
Have a qualified electrician replace the
up/down motor.
One phase lacks.
Check circuit breakers in the connectors.
Motor thermal protector started to
work.
Let the motor cool abd then reset the
thermal protector.
Speed switch circuit overloaded.
Turn off the power bad let the motor cool.
Turn the power back on.
Power feed is overheated.
Turn off the power abd let the motor cool.
Turn the power back on.
Short circuit in speed switch motor
system.
Have a qualified electrician remove the
short circuit.
Up/Down Or Power Feed
Switches Remain Engaged
When Switch Is Released.
Worn or dirty contacts in drum
switch.
Manually move the power feed or
up/down switch back to neutral or "off"
position. Replace drum switch or remove
control panel cover and clean and
lubricate contacts NOTE: Use only
contact grease supplied by Wood-Mizer.
Drum switch spring broken.
Manually move the power feed or
up/down switch back to neutral or "off"
position. Replace drum switch spring.
Up/Down Or Power Feed
Motors Overheat And Loose
Power.
System overload or bind occurred.
Correct problem.
Allow motor to cool
before restarting.
Normal operation factors exceeded
(eg: up/down control jockeyed
excessively).
Allow motor to cool before restarting.
Everything Works And Then
Cuts Out - Works Again.
Bad fuse, or ground connection.
Check and tighten connections.
Nothing Works Electrically.
Blown fuse.
Replace.