11
5.
ELECTRICAL INSTALLATION
5.1
Install a power supply at a switched fuse having a minimum separation of 3mm
at all poles. The spur should be readily accessible to the user, easily identifiable and
preferably sited adjacent to the appliance. It should only connect this appliance.
5.2
To simplify installation of the cable supplied, it may be most convenient to
disconnect it from the appliance as described below, install it to the wall and then
reconnect to the appliance:
To disconnect the cable:
1.
Detach the burner (See section 4.3).
2.
Detach the control unit from the convection box left side flange by removing two
screws (see figure 8). Carefully pull the unit slightly forward.
3.
Detach the control unit cover by removing one screw (See figure 9).
4.
Remove the cable by releasing the cable clamp and detaching the leads from
the terminal block and earth contact tag.
5.3
When installing the cable, leave a minimum of 200mm of the cable
slack at the cable clamp end to allow installation of the appliance after
reconnection to the control box and to allow future removal of the control box
for servicing.
5.4
If the spur is at the right side of the appliance, run the cable under the
hearth.
The cable must not run directly under or behind the appliance.
!
WARNING
:
Do not switch on the power supply until after the
fan cable has been correctly connected to the junction box - See
part 8.
Figure 9 Control cover fixing
Figure 8 Electrical control unit
fixings
Содержание Lincoln BR517S