14
7.
FAN BOX INSTALLATION
7.1
For transit purposes the fan mounting brackets are supplied fitted to the fan
box facing inwards. Remove them and refit as described below.
7.1.1
If the fan box is to be sited totally outside the wall fit the brackets with the
short flanges flush with the air intake end of the fan box (see figure 16).
7.1.2
If the fan box is to be recessed into the wall fit the brackets with the short legs
50mm from the air outlet face of the fan box (see figure 17).
7.2
Place the fan box in position with the duct connection spigot in the hole in
the wall and, if applicable, the fan box in the recess. Push the box in so that the fixing
brackets are against the wall and mark the screw fixing positions on the wall.
7.3
Remove the fan box. Drill the marked positions using a no.10 drill and plug
the holes.
7.4
Push the fan cable through the hole in the wall into the room.
7.5
Replace the fan box in position on the wall. Make sure when inserting the
duct connection spigot that its end does not cut into the cable.
7.6
Secure the fan box to the wall with the wood screws supplied.
7.7
Make good around the flue box ensuring that there are no gaps between the
fan box and wall.
Figure 17 For box recessed in wall
Figure 16 For box totally outside wall
Содержание Lincoln BR517S