25
15.
FINAL REVIEW
15.1
Make sure that the cast iron fire front is securely installed. See section 11. Place the bottom front casting in position.
15.2
Visually inspect the appliance. Clean off any marks incurred during installation.
15.3
Hand this guide, the owner’s guide and the smoke match tube to the customer.
15.4
Advise the customer how to operate the appliance. Point out that lighting instruction details are on a tie at the
bottom of the appliance.
15.5
Explain to the customer that the appliance has a flame failure & spillage monitoring system and that the gas supply to
the fire will be shut off unless the fan is in operation. Point out the explanation of this system shown in the users guide.
Mention that in windy weather or when the mains voltage is low, a slight click may be heard due to the fan control system
switching between its normal and boost speeds.
Advise that if the fire goes out for any reason, wait at least three minutes before relighting.
Stress that if the monitoring system repeatedly shuts off the fire, the appliance should be switched off and a specialist should
be consulted.
15.6
Advise the customer that they should read their Owner’s guide before operating the fire and always follow the advice
in the section headed “Cleaning your fire”.
15.7
Stress that no extra coals must be added over and above those supplied with the appliance and that any replacements must
only be the authorised spares. Warn that ignoring this advice could cause incomplete clearance of the products of combustion with
consequent health hazards.
15.8
Inform the customer that the gap between the top horizontal flange of the duct backing plates and the top rear of the
front covers must not be blocked. The gap is to allow cooling air circulation along the ducting run.
15.9
Recommend that the appliance should be serviced and the flue unit inspected by a competent person at least
annually. If the appliance is in premises in the United Kingdom occupied by a tenant, point out that by law a landlord must
have any gas appliance, flue and pipework which is situated in the tenants premises checked for safety at least every 12
months.