background image

25

15.

 

FINAL REVIEW

15.1

Make sure that the cast iron fire front is securely installed. See section 11. Place the bottom front casting in position.

15.2

Visually inspect the appliance. Clean off  any marks incurred during installation.

15.3

Hand this guide, the owner’s guide and the smoke match tube to the customer.

15.4

Advise the customer how to operate the appliance. Point out that lighting instruction details are on a tie at the

bottom of the appliance.

15.5

Explain to the customer that the appliance has a flame failure & spillage monitoring system and that the gas supply to

the fire will be shut off  unless the fan is in operation. Point out the explanation of this system shown in the users guide.
Mention that in windy weather or when the mains voltage is low, a slight click may be heard due to the fan control system
switching between its normal and boost speeds.
Advise that if the fire goes out for any reason, wait at least three minutes before relighting.
Stress that if the monitoring system repeatedly shuts off the fire, the appliance should be switched off and a specialist should
be consulted.

15.6

Advise the customer that they should read their Owner’s guide before operating the fire and always follow the advice

in the section headed “Cleaning your fire”.

15.7

Stress that no extra coals must be added over and above those supplied with the appliance and that any replacements must

only be the authorised spares. Warn that ignoring this advice could cause incomplete clearance of the products of combustion with
consequent health hazards.

15.8

 Inform the customer that the gap between the top horizontal flange of the duct backing plates and the top rear of the

front covers must not be blocked. The gap is to allow cooling air circulation along the ducting run.

15.9

Recommend that the appliance should be serviced and the flue unit inspected by a competent person at least

annually. If the appliance is in premises in the United Kingdom occupied by a tenant, point out that by law a landlord must
have any gas appliance, flue and pipework which is situated in the tenants premises checked for safety at least every 12
months.

Содержание Lincoln BR517S

Страница 1: ...I N S T A L L E R G U I D E For MODEL BR517S G C 3 2 0 3 2 1 2 S i d e F a n F l u e d I n s e t G a s F i r e with LINCOLN Front Please keep in a safe place for future reference 600B416 02...

Страница 2: ...us on 0121 386 6203 In the republic of Ireland call 353 183 75114 P l e a s e l e a v e t h i s I n s t a l l e r G u i d e w i t h t h e u s e r As supplied this appliance is for use with natural gas...

Страница 3: ...NSTALLATION 22 14 FULL OPERATING CHECKS 23 15 FINAL REVIEW 25 16 SERVICING PARTS REPLACEMENT 26 16 1 To Replace Burner Plaques See Figure 44 26 16 2 To Remove The Front Surround 27 16 3 To Remove The...

Страница 4: ...thing is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or d...

Страница 5: ...Rules for Electrical Installation 2 2 Electrical isolation of the unit should be by means of a switched fuse spur that should be readily accessible to the user easily identifiable and preferably sited...

Страница 6: ...6 Figure 1 General Installation Dimensions...

Страница 7: ...rround the burner bracket and the bottom front cover casting to be aligned horizontally Any excessive unevenness uneven tiles Cotswold stone etc should be rectified The appliance must not stand on com...

Страница 8: ...ld be located so that the wind can blow freely across it at all times and where any blockage due to leaves snow etc is unlikely The minimum allowable distances from the terminal are shown in the follo...

Страница 9: ...ls 1 Pipe bending template 1 Surround cutting metal template 1 Smoke match tube 1 Terminal weather shield 1 Junction box with cable clip earth lead sleeve fixings 1 Pack of fixings 1 Literature pack 1...

Страница 10: ...ob and while keeping it depressed turn anticlockwise through approximately 60 to the PILOT IGN position A spark should track from the electrode pin to the thermocouple tip If there is no spark or inco...

Страница 11: ...see figure 8 Carefully pull the unit slightly forward 3 Detach the control unit cover by removing one screw See figure 9 4 Remove the cable by releasing the cable clamp and detaching the leads from th...

Страница 12: ...om the rear left of the convection box Replace the screw thus removed into the convection box Clamp the cable at one of the screws at the right side of the box see figure 11 6 7 Fit the flue duct conn...

Страница 13: ...the outer wall make a rectangular opening as shown in figure 15 The depth of the recess is 145mm leaving the 50mm minimum projection required outside the wall Note that the fan box is not designed to...

Страница 14: ...nnection spigot in the hole in the wall and if applicable the fan box in the recess Push the box in so that the fixing brackets are against the wall and mark the screw fixing positions on the wall 7 3...

Страница 15: ...tween the top horizontal flanges or bottom angled flanges of the backing plates 8 3 Measure the length of the duct run between the intersection of the horizontal and sloping sections of the Z coupling...

Страница 16: ...fan cable into the C sections at the bottom of the support brackets see figure 24 8 11 Further support for the fan cable especially at corners can be provided using the spring cable clips supplied in...

Страница 17: ...he corners 8 15 For vertical duct installations Normally a false chimney breast will be constructed to hide the ducting The duct front covers will not therefore be required for these installations but...

Страница 18: ...erminal The fan should be heard to increase to boost speed within approximately two seconds iii Remove the hand The fan should revert to normal speed after approximately three seconds 9 6 The unit inc...

Страница 19: ...n position aligning the holes in the shield with those at the sides of the end plate Secure with the two screws previously removed see figure 32 10 3 Fit the terminal guard see figure 33 Secure the gu...

Страница 20: ...on box Carefully lift the cast front into position square with the convection box taking care not to damage the slide control mechanism Holding the cast front a little above the top surface of the con...

Страница 21: ...ght ensure that the air has been purged that the pilot orifice is clear and that the thermocouple connections are sound Replace the pilot unit if necessary see servicing section of this manual 12 3 7...

Страница 22: ...ner compartment and its rear face should touch the rear ceramic wall See figure 39 13 4 Install the 9 loose coals as follows The smooth surfaces of the coals should be at the bottom and back 13 4 1 Se...

Страница 23: ...depress the control knob and turn to OFF The pilot should be extinguished 14 1 10 Press the off switch to turn off the fan the indicator light should glow 14 2 Check For Spillage A spillage check must...

Страница 24: ...for one minute 14 3 2 Turn back to OFF to extinguish the pilot Note the time when the pilot goes out Listen for a snap sound at the gas tap Note the time when the sound is heard This sound is caused...

Страница 25: ...s that if the monitoring system repeatedly shuts off the fire the appliance should be switched off and a specialist should be consulted 15 6 Advise the customer that they should read their Owner s gui...

Страница 26: ...lls and coals are replaced correctly as described in the installation instructions Always test for gas soundness and spillage after servicing the appliance and check operation of all controls Do not u...

Страница 27: ...disconnect the appliance from the elbow 16 3 4 Detach the burner unit from the convection box by removing 2 screws see figure 46 Carefully lift the burner unit forward making sure that the unit does n...

Страница 28: ...ove the gas tap solenoid unit as sections 16 5 1 to 16 5 12 16 6 2 Make sure that the tap is in the off position 16 6 3 Remove the circlip holding the piezo unit to the tap Remove the piezo unit 16 6...

Страница 29: ...witch see figure 53 16 10 5 Disconnect the three leads Yellow orange white from the air pressure switch 16 10 6 Disconnect the two leads Brown blue from the mains cable connection block 16 10 7 Replac...

Страница 30: ...weather shield and flue box end plate by removing two screws see figure 55 16 12 3 Disconnect the wiring loom connector inside the top right of the flue box see figure 56 15 12 4 Slide the fan out of...

Страница 31: ...709 D Gas tap spark generator 1 545969 E Spark generator 1 521069 F Control knob 1 545979 G Pilot unit For Natural Gas Appliances 1 540979 Pilot unit For Propane Appliances 544929 H Solenoid valve 1 5...

Страница 32: ...tered Installer Please fill in the following information for your own future reference The information should always be quoted in any correspondence with your original supplier or Wonderfire service d...

Отзывы: