background image

 

At the 

Modem 

part, first you can the 

module’s 

MEID 

identifier (IMEI) and the 

SIM ID

 identifier of 

the used SIM card.  
You can also check the wireless modem availability, current status and health at 

Modem RSSI

 

(cellular network signal strength) and 

Modem

 

SQ. (

The lower RSSI means better cellular signal 

strength / higher SQ value means the better signal quality level).

 

 
At

 

the

 CREG 

field

 

you can get more info about the used cellular network cells. The 

COPS

 shows 

the connected network name. 
 

 

 
At the 

Network

 part, you can see the used cellular network IP address at the 

Address field

.  

 

Содержание E LCB

Страница 1: ...WM E LCB Load Control Box User Manual v1 00 _________________________________________ 2021 11 02...

Страница 2: ...operation of the device Document category User Manual Document subject WM E LCB Author WM Systems LLC Document version No REV 1 00 Number of pages 60 Hardware version BE0080B Linux Kernel 4 9 184 Boo...

Страница 3: ...3 Ethernet LAN settings 17 3 4 DHCP and DNS settings 18 3 5 Defining route rules Static routes 21 3 6 Firewall settings 22 3 7 Port Forward settings 26 3 8 NAT settings 26 CHAPTER 4 ADVANCED SERVICES...

Страница 4: ...ettings 48 5 6 Clone config backup restore 48 CHAPTER 6 ADMINISTRATION 50 6 1 Password change 50 6 2 Logging 51 6 3 Language settings 51 6 4 Periodic reboot settings 52 6 5 Periodic ping 52 6 6 Instal...

Страница 5: ...s on your PC for TCP IPv4 protocol for setup the IP address 192 168 127 100 and subnet mask 255 255 255 0 2 Start the device The local web user interface LuCi will be reachable after 1 2 minutes throu...

Страница 6: ...current status of the device At the System part you can check the installed software build Firmware Version where it should be 202108271_RC or newer If it has an older version then refresh the firmwar...

Страница 7: ...health at Modem RSSI cellular network signal strength and Modem SQ The lower RSSI means better cellular signal strength higher SQ value means the better signal quality level At the CREG field you can...

Страница 8: ...eriodic ping and reboot Factory configuration Relay switch settings Services Ser2net RS485 configuration Network Network interface settings for Ethernet and cellular module DHCP DynDNS IP route NAT ho...

Страница 9: ...pplications for the Linux distribution You can define the Startup applicatons Initialization of programs can be configured during the operation and the Scheduled Tasks The LED Configuration is also co...

Страница 10: ...t You can define the DHCP and DNS settings for the wireless LTE module and connection Define Hostname for the modem for easier identification of the device on your network At the Static Routes are als...

Страница 11: ...t using actively or which are not necessary to the connection and data transmitting by respecting the ports which are necessary for the general operation Use to check Status Firewall menu to check the...

Страница 12: ...Note that we offer to use 9 600 baud or 2 400 baud speed rate which is standard and there can be guaranteed that it will work With higher data speed rates some connected systems can cause loss of char...

Страница 13: ...ans the wireless Internet connection as 4g wan the physical 4G cellular module Modifying the interface settings At the interfaces at right you can modify the settings with the button The Stop button s...

Страница 14: ...can be operated through the dynamic and static IP address IPv4 assignment also which is provided by your mobile operator At the General Setup tab you can see the current status of the interface with...

Страница 15: ...de if you choose the 4G and it the network will be not available there will not be provided 3G or 2G fallback if the choosen network is not available the device won t get mobile network access For fal...

Страница 16: ...terface status at the Interfaces part The device is already connected to the cellular network it has active data traffic and the RX received data TX transmitted data at Pkts number of network packets...

Страница 17: ...ng the Network Interfaces menu item At the LAN interface s button choose the General Setup tab By default the Ethernet IP address is static the default IP address is 192 168 127 1 If you want to switc...

Страница 18: ...g is the Static Address and the IP address should be also changed and you have to uncheck the DHCP disabled option for the LAN interface to allow the DHCP server Save your settings by the Save Apply b...

Страница 19: ...used by the router in our case 192 168 x Use the Limit field to limit how many IP addresses are assigned That is the router on subnet 192 168 x will assign IP addresses in the address range between S...

Страница 20: ...can see and configure them under the General Settings tab At the Static Leases you can add network devices by the button to be guaranteed to get the same IP address after every leade time renewal Defi...

Страница 21: ...The current IP Route settings can be checked in the Status Routes menu We offer to check the currently used route rules ARP routes and the IPv4 and IPv6 route rules To modify the settings or define n...

Страница 22: ...which is unnecessarly decrease the available data package amount of the SIM card in the modem You can check all of these at the Status menu Realtime Graphs item at the Connections tab where these can...

Страница 23: ...vice and subnet Another method for limitation is to disable all ports to open and enable only the necessary and used communication ports define the used IP address range by allowing exact IPs You can...

Страница 24: ...ngs or modify Below at Zones part you can a new rule to the current ones You also can or an existed rule Save modified settings by Save Apply button When you d like to add new rule to the firewall set...

Страница 25: ...settings Don t forget to the old not relevant rule for the service For modifying the Firewall settings choose button For the port level filtering or interface traffic limits or Traffic Rules settings...

Страница 26: ...e and Internal zone Ports External ports Internal ports and the Internal IP address values When you modified the settings save them by the Save Apply button 3 8 NAT settings In the Network menu Firewa...

Страница 27: ...ta which incoming IP address and port must be redirected to which outgoing IP address and port and must be forwarded the data traffic You also can define a port range hereby When you modified the sett...

Страница 28: ...lways limit the access of services and decrease the amount of the throughput communication on the network by these rules to provide the operation only for the necessary services ports ip addresses Whe...

Страница 29: ...P Important This NTP time synchronisation is highly important for data storage of the incoming readout results metering files on the modem s memory Because the device uses file syntax with the current...

Страница 30: ...tion part allow to Enable NTP client option and define an NTP server IP address NTP server candidates If you allow the Provide NTP server option the connected device s will getting NTP time from the W...

Страница 31: ...ified the settings save them by the Save Apply button The local hostname for the modem which name will appear for external devices on the network it can be changed at the System System menu item where...

Страница 32: ...Network boot image Of course you can also use SFTP on your device by sending the data to IP addresses by entering your account and password information if you need more help see Chapter 9 in the OpenS...

Страница 33: ...l conversion parameter settings such as receiving the incoming communication in the proper format and data exchange For first the RS485 feature must be enabled and RS485 cabling of RJ45 port must be c...

Страница 34: ...1STOPBIT 7DATABIT EVEN For lower speed 8N1 mode use this one 2400 1STOPBIT 8DATABIT NONE Important Note that maximum 115 200 baud speed rate can be used wheather of the configuration options But we of...

Страница 35: ...mode field which is for protocol compatibility It has the following protocol conversions to be selected ON 1107 IEC 1107 protocol compatible mode OSLP Open Street Light Protocol compatible mode ON 11...

Страница 36: ...ich means 19200 baud When you modified the settings save them by the Save Apply button 4 7 LED configuration The device has 5 LEDs to assign the current relay switch status and network connection The...

Страница 37: ...menu will appear At the Trigger mode the Link On network activity Transmit data transmitting or Receive data receive can be choosed for signing the data flow or activity by he LED flashing When you ha...

Страница 38: ...u want to use IPSEC Below in the IKEv1 Phase1 Phase2 settings you can use the button to give a logical name to the IPSEC connection then select the Encryption algorithm and Hash algorithm and set the...

Страница 39: ...name of the IKEv1 Phase 2 option is an optional name where you must specify the Key exchange method Below in the Connection name section you can enable or disable the connection Enable Disable connect...

Страница 40: ...mode can be main or aggressive Enter the keys for the Local gateway identifier and the Remote gateway identifier When you have modified the settings save them by the Save Apply button You can read mor...

Страница 41: ...wed assigned phone number the device runs a reboot command You can also use the button to add additional phone numbers and select the reboot command for the phone numbers Press the Save Apply button t...

Страница 42: ...rom a preset phone number the device runs the preset command s assigned to the phone number e g Reboot For other commands the device returns the information in a reply SMS message e g when sending the...

Страница 43: ...s fwos BE0080x_WM E_LCB 202108271_RC tar gz 2 Open the System menu Backup Flash Firmware menu item 3 At first just by safety backup your system before changing the firmware version see the instruction...

Страница 44: ...n the browser that he refresh method has been started 7 All network connections will be disconnected during the installation When the firmware installation begins the WAN LED will assign the installat...

Страница 45: ...device will disconnect the LAN and WAN network interfaces which will be signed after 5 10 seconds by the blank WAN LED REL 1 REL 2 REL 3 REL 4 WAN Then the device will be restarted and after 1 2 minut...

Страница 46: ...ed anytime again by adding the power source for the device connect the AC power plug to the electricity network The device will be operating as it is written in the Installation Manual Chapter 2 2 5 4...

Страница 47: ...files scripts and directories manually by your own You can include or exclude your files and directories in your backup process by using the Configuration tab here You can edit the list with all neces...

Страница 48: ...nd applying the previously used configuration Important Note that your custom saved settings must be loaded seperately it won t be restored automatically 5 6 Clone config backup restore The device cur...

Страница 49: ...mputer Save the file please This is very helpful to move the saved configuration file to your computer and then later restore these settings to a different modem device by the Browsing and then the bu...

Страница 50: ...imum 3 special characters upper case numbers or special characters e g underline The currently used Password cannot be seen here due to some security rules the characters shown as are empty here When...

Страница 51: ...h When you have modified the settings save them by the Save Apply button Remember that you can use further log features from the Status menu where the System log the Kernel Log helps you to understand...

Страница 52: ...er language settings Push to the Save Apply button when you have changed the language then the new language translated texts will appear 6 4 Periodic reboot settings For matching the industrial standa...

Страница 53: ...ping interval is normal not signed as a fail error Ping interval length of ping running in seconds e g 60 means ping for 1 minute Save your settings by the Save Apply button 6 6 Installing 3rd party...

Страница 54: ...ion or use it E g about our example enter the mc to start the Midnight Commander tool which you were installed from the repository 6 7 SSH access You can access the device remotely according the curre...

Страница 55: ...ty reasons SSH login data Login root Password wmrpwdM2M Now you are logged in at the OpenWrt s command line Here you can use Linux commands or using scripts or the uci commands on the device Check cha...

Страница 56: ...mserver com en product device manager The Device Manager settings can be defined in the Router Device Manager menu The main importants are the DM IP Address the DM Port Number and DM User Name The def...

Страница 57: ...wiring SIM card is not detected Ask you Mobile Operator about the SIM card is healthness and activation APN SIM APN failure Always check the Status Overview menu first at the SIM ID field for the cur...

Страница 58: ...about the SIM card is condition and activation status correct APN name and configure the modem with the new information If it does not help ask the Installation expert person Cannot access the device...

Страница 59: ...support questions the product identifier is important for resolve your problem Please when you are attempting to tell us an incident please send us the IMEI and SN serial number information from the p...

Страница 60: ...he pictures in the user guide are only for illustration purposes WM Systems LLC does not confirm or accept responsibility for any mistakes in the information contained in the user guide The published...

Отзывы: