If you need dialup connection for using the Internet service at your provider, set the
Dial
number
value (format: *99***1# ).
In case of roaming change the
Mobile country code
(MCC) settings to the related country code
please. If you are attempting to use a dedicated cellular network, configure the MNC field (
Mobile
network code
) please, according the needs. You will found the currently useable MCC / MNC
settings here:
Click to the
Save & Apply
button for saving the settings, while the device will be restarting the
cellular module with the new settings and will connecting to the cellular network.
Then, you can check the data transmitting at the
Network
/
Interfaces
menu, when check the
WAN
interface status at the
Interfaces
part.
The device is already connected to the cellular network, it has active data traffic and the
RX
(received data),
TX
(transmitted data) at
Pkts.
(number of network packets)
and
KB
(KBytes)
values are growing.
The
WAN
interface data traffic will be signed by the
red
flashing of the
WAN
LED (together with
the
green
flashing of the
LAN
)
–
which all can be indentified as
yellow
.
At the
Advanced Settings
tab you will found further settings for the wireless module.
By default we do not offer to change these settings, only if you are special requirements at operating
the mobile network communication by the modem (these are the
LCP Echo
settings, the
Bring up
on boot
and the
use built-in
IPv6 management
parameters mainly).
If you changed the configuration here, click upon
Save & Apply
button for saving the settings.