ENGLISH
ITALIANO
REV. 00
139
/ 164
WM LIGHT
/
WM LIGHT-R
/
WM LIGHT FIXED
> PROBLEMA (4)
Rumorosità in fase di apertura/chiusura
o rotazione della rampa.
> CAUSA — — — — — — — — —
(1) Insufficiente lubrificazione.
(2) Boccole o perni usurati
(B2 - Fig. 109).
> RIMEDIO — — — — — — — —
(1) Lubrificare adeguatamente.
(2) Sostituzione particolari usurati.
(3) Verificare eventuali punti di contatto
bandelle. Applicare mousse adesiva
se necessario.
> PROBLEMA (5)
La rampa aperta si flette quando è sotto
carico.
> CAUSA — — — — — — — — —
(1) Suolo non in piano o non adeguato.
(2) Carico che eccede la portata MAX.
> RIMEDIO — — — — — — — —
(1) Operare su suolo adeguato.
(2) Rispettare i limiti di portata MAX.
> PROBLEMA (6)
La rampa chiusa oscilla eccessivamente.
> CAUSA — — — — — — — — —
(1) Viti di fissaggio base non serrate.
> RIMEDIO (Fig. 110) — — — — —
(1) Regolare i tamponi di appoggio T.
(2) Regolare il gancio di sicurezza G.
(3) Verificare il serraggio di maniglie e
pomolo di fissaggio.
(4) Verificare il perfetto appoggio, in
ogni punto, della base B sul pianale.
> PROBLEMA (7)
La rampa sembra essere diventata più
pesante in fase di apertura o chiusura.
> CAUSA — — — — — — — — —
(1) Perdita di efficienza molle di bilan-
ciamento-contrappeso.
Molle scariche.
(2) Insufficiente lubrificazione perni.
> RIMEDIO — — — — — — — —
(1) Ripristinare efficienza molle / sosti-
tuirle.
(2) Lubrificare perni / cerniere.
> PROBLEM (4)
Noise when opening/closing or rotating
the ramp.
> CAUSE — — — — — — — — —
(1) Insufficient lubrication.
(2) The bushings or pins are worn
(B2 - Fig. 109).
> SOLUTION — — — — — — — —
(1) Lubricate correctly.
(2) Replace any worn parts.
(3) Check to see if the hidden hinges
touch anywhere. Apply adhesive
mousse if necessary.
> PROBLEM (5)
The opened ramp bends under weight.
> CAUSE — — — — — — — — —
(1) The ground is not flat or is inappropriate.
(2) The load exceeds the MAX. capacity.
> SOLUTION — — — — — — — —
(1) Work on appropriate ground.
(2) Respect the MAX. capacity limits.
> PROBLEM (6)
The closed ramp oscillates excessive-
ly.
> CAUSE — — — — — — — — —
(1) The base fastening screws are not
tightened.
> SOLUTION (Fig. 110) — — — — —
(1) Adjust the support buffers T.
(2) Adjust the safety catch G.
(3) Make sure the handles and faste-
ning knob are tightened.
(4) Make sure the base B rests perfectly
on the floor at every point.
> PROBLEM (7)
The ramp seems heavier when opening
or closing it.
> CAUSE — — — — — — — — —
(1) The counterweight-balancing
springs have lost their efficiency.
Stretched springs.
(2) Insufficient pins lubrication.
> SOLUTION — — — — — — — —
(1) Restore the efficiency of the springs
/ replace them.
(2) Lubricate the pins / hinges.
G
B
T
Fig. - Abb. 110