Translation of the original operation manual
DUOMIX 230
29
DM230_BAoDB_en_1307 · rs
Transport, installation and assembly
The
DUOMIX 230
comes with a ground cable as standard.
This cable is already connected to one of the high pressure
filters upon delivery.
In order to ground the unit, the clamp of the ground cable is
connected to an electrically conductive object.
Fig. 26: Erdungskabel am Hochdruckfilter
4.3.5 Filling in release agent and pneumatic oil
If the unit is delivered in horizontal position (version with wall bracket), any
release agent and pneumatic oil has been drained off. In this case you must fill
in both operating media before initial start-up (see chapter 6.3.1 on page 37
and chapter 6.4 on page 38).
4.3.6 Assembling the hose package and the external mixing unit (optional)
WARNING
If the hose package couplings are subjected to tensile load, these assem-
blies may be torn out. Material escaping under high pressure can cause
injuries and material damage.
➤
If tensile loads on the hose package couplings are to be expected (e.g.
by positioning the mixing unit), a strain relief is required!
If the hose package is too tightly bent, hoses may buckle inside the hose
package.
➤
The minimum bending radius of 30 cm must not be fallen short of!
Fig. 27: Hose package connections on adapter
Nr. Connection
1
Flow of A-component
2
Return flow of A-component
3
Flushing
4
Return flow of B-component
5
Flow of B-component
1
2
3
4
5
Nr. Connection
1
Flushing
2
Return flow of B-component
3
Flow of B-component
4
Flow of A-component
5
Return flow of A-component
Fig. 28: Hose package connections on the external mixing unit
1
2
3
5
4