30
Translation of the original operation manual
DUOMIX 230
DM230_BAoDB_en_1307 · rs
Operation
5 Operation
Before starting operation, check:
5
Are all safety features of the unit present and fully functional?
5
Are all components of the unit leak tight? If necessary, re-tighten the con-
nections.
5
Is the oil reservoir of the fog oiler filled with an appropriate amount of lubri-
cant?
WARNING
If fluid pumps run dry, the generated friction heat can cause fire or an ex-
plosion.
➤
Always make sure that the material drums do not run dry during opera-
tion.
➤
However, should this happen, stop the corresponding pump immediately
and feed material.
During work the flushing pump should always be ready for use, so that all
components, which come in contact with the mixed material, can be flushed
within the specified potlife!
5.1 Taking the unit into service
Requirements:
➤
The unit must be properly placed and completely assembled.
➤
Do not start commissioning the unit unless you have the specified
protective equipment. For details on this topic, refer to chapter 2.5.4 on
page 13.
➤
The material to be applied must be available in sufficient quantities.
Furthermore you need two appropriate containers for collecting excess
material. These containers are not included in the scope of delivery.
Observe the technical notes of the respective material manufacturer.
Check the tightness of the unit or single components of the unit by slow pres-
sure build-up during the commissioning.
1.
Place the suction pipe of the flushing pump into the flushing agent drum.
2.
Make sure that all air pressure regulators have been fully regulated back.
3.
Open the compressed air shut-off valve on the air maintenance unit.
4.
Set the levers at the mixing unit to “Flush”
5.
On the pressure regulator of the flushing pump set a pressure of 3 - 6 bar,
depending on the length of the material hoses.
6.
Open the spray gun, until clean flushing agent starts to run out.
7.
Only on versions with pressure and dosing control (see chapter 3.6.1 on
page 25): Set the switch “Manual / Automatic” to “Manual” and press the
start button.
Содержание Duomix 230
Страница 2: ......