background image

 

WL

-

430T    4G Wireless Modem with all function

                                                                               

UserManual

 

   

 

 

 

 

Advanced Firewall Features

 

Network Address Translation (NAT)

 

 

 

 

 

State full Packet Inspection (SPI) 

 

 

  

Port Forward, Packets 

 

 

  

 

 

 

 

Media Access Control

 

CSMA/CA with ACK

 

 

 

 

 

 

 

 

 

GPS

 

According to the NMEA-0183 protocol

 

 

 

 

 

 

 

 

 

Network Function

 

WiVPN, DHCP, DNS, DDNS, ICMP

 

 

 

 

 

 

 

 

 

IO Function

 

DI×2

DO×2

AI

4-20mA

×1

 

 

 

 

 

 

 

 

 

Hardware Specifications

 

 

 

 

 

Size

 

Width 5.3 inches x Height 3.7 inches x Depth 1.6 
inches

 

 

 

 

 

 

 

 

 

Weight

 

1.2 lbs 

543g

 

 

 

 

 

 

 

 

 

Enclosure

 

Aluminum DIN-Rail

 

 

 

 

 

 

 

 

 

Interface

 

2×RJ45

10/100Mbps

),

1×Rs232

I/O Port(2×DI

2×DO

1×AI)

 

 

 

 

3× SMA

1× RS485

1X1.8V/3V SIM slot

 

 

 

  

 

 

 

 

Operation Temperature

 

-20

 - 65

 

 

 

 

 

 

 

 

 

Storage Temperature

 

-30

 - 70

 

 

 

 

 

 

 

 

 

Humidity

 

95% Maximum (Non-condensing)

 

 

 

 

 

 

 

 

 

Power

 

10-31VDC

 

 

 

 

 

 

 

 

 

Power consumption

 

Idle: 130mA@24VDC 

Max: 250mA@24VDC

 

Average:160mA@12VDC

 

 

 

 

 

 

 

 
 

 

1.2 Package Contents 

 
 

The following components are included with theWL-430T-A/AK/LT/G/IO/S, 
and are required for installation and configuration. 

 

Important: 

Before beginning the installation, please verify that 

all of the

 

following items are present 

 

Qty 

Part No. 

Part Name 

PART DESCRIPTION 

 

 

 

 

WL-430T-A 

3G/4G Industrial Modem 

3G/4G Wireless Modem with all 

 

 

 

function 

 

 

 

 

WL-0702-O 

3G/4G Antenna 

3G/4G Omni Antenna(700MHz- 

 

 

 

2700MHz) 

 

 

 

 

WL-2502-O 

2.4GHz/5GHz Antenna 

2.4GHz/5GHz 2dBi Omni Antenna 

 

 

 

 

WL-003T-A 

3-pin Power Plug 

Mating connector used for attachment 

 

 

 

to customer’s power supply

 

 

 

 

 

WL-010T-A 

10-pin IO Plug 

Mating connector used for attachment 

 

 

 

to customer’s IO Signal and Rs485

 

 

If any of these components are missing, please contact WitLinc Technology 
Support for replacement parts.

   

Содержание WL-430T-A

Страница 1: ...WL 430T 4G Wireless Modem with all function UserManual Connected Machines Anywhere Anytime WL 430T 3G 4G Wireless Modem WL 430T A LT G IO S AK Version 2 1 0 1 Jan 01 2016 User Manual...

Страница 2: ...ssumes no liability for and reserves the right to correct such inaccuracies or errors at any time without notice If you have any suggestions for improvements or amendments or have found errors in this...

Страница 3: ...g The RS 232 serial connector Ethernet connector and I O terminal block are not for use in Hazardous Locations they are only for diagnostics and set up only Warning When Antenna is installed into ulti...

Страница 4: ...the WL 430T A IP address 9 2 3 Setup WL 430T A Cellular Provider 10 2 4 Setup the WAN Interface 11 2 5 Setup the WiFi Function 12 2 6 Setup the WiVPN Function 15 3 Hardware Installation 18 3 1 Power...

Страница 5: ...re on site Allowing HMI PLCs sensors etc to communicate with each other Remote Access removes boundaries eliminates the need for time consuming site visit and provide a network infrastructure suitable...

Страница 6: ...1VDC Power consumption Idle 130mA 24VDC Max 250mA 24VDC Average 160mA 12VDC 1 2 Package Contents The following components are included with theWL 430T A AK LT G IO S and are required for installation...

Страница 7: ...t 128 Mbytes of RAM minimum 256 Mbytes of RAM recommended 100 Mbytes of free hard disk space or more based on application requirements 256 color VGA graphics adapter 800 x 600 minimum resolution True...

Страница 8: ...e devices parameters Connection Status Interface Configurations Wireless Configurations WiVPN Configurations 2 1 Configuration Webpage Setup 1 The default IP address of the WL 430T A is 192 168 8 1 An...

Страница 9: ...enter the USERNAME and PASSWORD to login The default Username is witlinc and the default Password is admin 4 After successful login the main configuration webpage will be displayed 2 2 Setup the WL 4...

Страница 10: ...s the configuration webpage 2 3 Setup WL 430T A Cellular Provider The WL 430T A supports 4G GSM HSUPA networks Only one network will be supported at a time It uses your cellular provider as an ISP Int...

Страница 11: ...address from your cellular provider a connection to the Internet or the cellular network is also available for computers or other devices to connect directly to the WL 430T A 6 The GSM network inform...

Страница 12: ...etwork A Provider Then the WAN Port will receive a static IP address or a dynamic IP address automatically After the Protocol configuration complete Click the Save Apply the module will reboot After t...

Страница 13: ...mode SSID Encryption If you want to connect to a excisted WiFi please scroll down your mouse to the SCAN and click it then can brows which you need If you want want use the module as WiFi master or o...

Страница 14: ...an decipher and understand it Although none is an available encryption type Witlinc Technology strongly recommends encrypting all data sent and received from every radio on your network to help preven...

Страница 15: ...uthentication a VPN connection would be established Below are steps to make connection to a WiVPN server 1 Before config WiVPN client you need to get 3 files from WiVPN server administrator ca crt cli...

Страница 16: ...7 Type in cipher upload ca crt to ca field upload clientX crt to cert field and upload clientX key to key field As show below the cipher is AES 256 CBC If no corresponded fields exist scroll down the...

Страница 17: ...files to corresponded fields click SAVE button as show below 9 Through web management interface Services WiVPN check Enabled checkbox and click SAVE button As show below 10 Wait a while you can see t...

Страница 18: ...e to the power terminal Please be careful don t connect the positive to the negative terminal Negative Positive 2 Insert the Power Terminal into the module then tighten the screws 3 2 Antenna installa...

Страница 19: ...e antenna onto the antenna port connector until it is snug The frequency range must between 700MHz 2700MHz 2 Screw the WiFi antenna onto the WiFi antenna port connector the WiFi frequency range must b...

Страница 20: ...s on the module We can monitor the IO signal by the Serial port Also the IO signal can be controlled by the serial port DO 2 Digital Output Signal No 2 terminal DO 1 Digital Output Signal No 1 termina...

Страница 21: ...re are two serial cable one cable is RJ45 to DB9 Female connector and another is the serial Null Modem cable DB9 to RJ45 Cable RS 232 Modem Connection Hardware Handshaking Required This type of connec...

Страница 22: ...ameter for the port configuration should be set to Y for most modem applications RS 232 Null Modem Connection Hardware Handshaking This type of connection is used when the device connected to the modu...

Страница 23: ...ses installing a 120 ohm terminating resistor between pins Rs485 and Rs485 on the module connector end of the RS 485 line may improve communication quality RS 485 and RS 422 Tip If communication in th...

Страница 24: ...ernet Cable has been detected WAN Green Steady WAN port Communication Failed Green Flashing WAN port Communication is ok Unlighted No Ethernet Cable has been detected WiFi Green Steady WiFi Function i...

Страница 25: ...mation 4 LED patterns 5 Details about the serial Ethernet or other interfaced to the module Note For technical support calls within the United States an emergency after hours answering system allows 2...

Отзывы: