background image

 

WL

-

430T    4G Wireless Modem with all function

                                                                               

UserManual

 

20 

 
 

Important: 

Antennas  selected  should  not  exceed  a  maximum 

gain of

 

5 dBi under standard installation configuration. In more 

complex  installations,  it  is  imperative  that  the  installer  follow 
maximum  dBi  gain  guidelines  in  accordance  with  the  radio 
communications 

regulations 

of 

the 

Federal 

CommunicaCommission  (FCC),  Industry  Canada,  or  your 
country's regulatory body (if used outside the Canada). 

 

3.3

 

IO terminal installation 

There are two digital input/output and one analog terminals on the module. 
We  can  monitor the  IO signal  by  the  Serial port.  Also  the  IO  signal  can be 
controlled by the serial port. 

 

 

DO-2 

Digital Output Signal No.2 terminal 

  

 

 

DO-1 

Digital Output Signal No.1 terminal 

  

 

 

DO-C 

Digital Output ground terminal 

  

 

 

DI-2 

Digital Input Signal No.2 terminal 

  

 

 

DI-1 

Digital Input Signal No.1 terminal 

  

 

 

DI-C 

Digital Input ground terminal 

  

 

 

AI+ 

Analog input positive terminal 

  

 

 

AI- 

Analog input negative terminal 

  

 

 

Rs485 + 

Rs485 positive terminal 

  

 

 

Rs485 - 

Rs485 Negative terminal 

  

 

 

3.4

 

Rs232 Serial port installation 

The  use  of  hardware  handshaking  (control  and  monitoring  of  signal  lines) 
depends  on  the  requirements  of  the  networked  device.  If  no  hardware 
handshaking  will  be  used,  the  cable  to  connect  to  the  port  is  as  shown 
below: 

 

Содержание WL-430T-A

Страница 1: ...WL 430T 4G Wireless Modem with all function UserManual Connected Machines Anywhere Anytime WL 430T 3G 4G Wireless Modem WL 430T A LT G IO S AK Version 2 1 0 1 Jan 01 2016 User Manual...

Страница 2: ...ssumes no liability for and reserves the right to correct such inaccuracies or errors at any time without notice If you have any suggestions for improvements or amendments or have found errors in this...

Страница 3: ...g The RS 232 serial connector Ethernet connector and I O terminal block are not for use in Hazardous Locations they are only for diagnostics and set up only Warning When Antenna is installed into ulti...

Страница 4: ...the WL 430T A IP address 9 2 3 Setup WL 430T A Cellular Provider 10 2 4 Setup the WAN Interface 11 2 5 Setup the WiFi Function 12 2 6 Setup the WiVPN Function 15 3 Hardware Installation 18 3 1 Power...

Страница 5: ...re on site Allowing HMI PLCs sensors etc to communicate with each other Remote Access removes boundaries eliminates the need for time consuming site visit and provide a network infrastructure suitable...

Страница 6: ...1VDC Power consumption Idle 130mA 24VDC Max 250mA 24VDC Average 160mA 12VDC 1 2 Package Contents The following components are included with theWL 430T A AK LT G IO S and are required for installation...

Страница 7: ...t 128 Mbytes of RAM minimum 256 Mbytes of RAM recommended 100 Mbytes of free hard disk space or more based on application requirements 256 color VGA graphics adapter 800 x 600 minimum resolution True...

Страница 8: ...e devices parameters Connection Status Interface Configurations Wireless Configurations WiVPN Configurations 2 1 Configuration Webpage Setup 1 The default IP address of the WL 430T A is 192 168 8 1 An...

Страница 9: ...enter the USERNAME and PASSWORD to login The default Username is witlinc and the default Password is admin 4 After successful login the main configuration webpage will be displayed 2 2 Setup the WL 4...

Страница 10: ...s the configuration webpage 2 3 Setup WL 430T A Cellular Provider The WL 430T A supports 4G GSM HSUPA networks Only one network will be supported at a time It uses your cellular provider as an ISP Int...

Страница 11: ...address from your cellular provider a connection to the Internet or the cellular network is also available for computers or other devices to connect directly to the WL 430T A 6 The GSM network inform...

Страница 12: ...etwork A Provider Then the WAN Port will receive a static IP address or a dynamic IP address automatically After the Protocol configuration complete Click the Save Apply the module will reboot After t...

Страница 13: ...mode SSID Encryption If you want to connect to a excisted WiFi please scroll down your mouse to the SCAN and click it then can brows which you need If you want want use the module as WiFi master or o...

Страница 14: ...an decipher and understand it Although none is an available encryption type Witlinc Technology strongly recommends encrypting all data sent and received from every radio on your network to help preven...

Страница 15: ...uthentication a VPN connection would be established Below are steps to make connection to a WiVPN server 1 Before config WiVPN client you need to get 3 files from WiVPN server administrator ca crt cli...

Страница 16: ...7 Type in cipher upload ca crt to ca field upload clientX crt to cert field and upload clientX key to key field As show below the cipher is AES 256 CBC If no corresponded fields exist scroll down the...

Страница 17: ...files to corresponded fields click SAVE button as show below 9 Through web management interface Services WiVPN check Enabled checkbox and click SAVE button As show below 10 Wait a while you can see t...

Страница 18: ...e to the power terminal Please be careful don t connect the positive to the negative terminal Negative Positive 2 Insert the Power Terminal into the module then tighten the screws 3 2 Antenna installa...

Страница 19: ...e antenna onto the antenna port connector until it is snug The frequency range must between 700MHz 2700MHz 2 Screw the WiFi antenna onto the WiFi antenna port connector the WiFi frequency range must b...

Страница 20: ...s on the module We can monitor the IO signal by the Serial port Also the IO signal can be controlled by the serial port DO 2 Digital Output Signal No 2 terminal DO 1 Digital Output Signal No 1 termina...

Страница 21: ...re are two serial cable one cable is RJ45 to DB9 Female connector and another is the serial Null Modem cable DB9 to RJ45 Cable RS 232 Modem Connection Hardware Handshaking Required This type of connec...

Страница 22: ...ameter for the port configuration should be set to Y for most modem applications RS 232 Null Modem Connection Hardware Handshaking This type of connection is used when the device connected to the modu...

Страница 23: ...ses installing a 120 ohm terminating resistor between pins Rs485 and Rs485 on the module connector end of the RS 485 line may improve communication quality RS 485 and RS 422 Tip If communication in th...

Страница 24: ...ernet Cable has been detected WAN Green Steady WAN port Communication Failed Green Flashing WAN port Communication is ok Unlighted No Ethernet Cable has been detected WiFi Green Steady WiFi Function i...

Страница 25: ...mation 4 LED patterns 5 Details about the serial Ethernet or other interfaced to the module Note For technical support calls within the United States an emergency after hours answering system allows 2...

Отзывы: