72_
setup
setup
To set troubleshooting
1.
Set one recorder to <
Standby
> mode and the other recorder to <
Active
> mode.
2.
In the recorder set to <
Active
> mode, enter the viewer port IP and administrator password of the <
Standby
>
recorder you want to connect to and click <
Connection
> under the status display.
3.
Check the IP and status of the connected <
Active
> recorder in the <
Standby
> recorder.
Setup > Network > failover
●
Mode : Select either <
Active
> or <
Standby
> mode.
– Active : Recorder being recorded. Monitored by the <
Standby
> recorder.
– Standby : Recorder being prepared without recording. It will record instead of the <
Active
> recorder if a
problem occurs.
In the case of active mode
●
Standby recorder IP : Enter the viewer port ID of a standby recorder to access.
●
Standby recorder password : Enter the administrator password of the standby recorder.
●
Status : Displays the current connection status.
●
Connection / Disconnection : Click the button to access or disconnect the access.
In the case of standby mode
●
Device list & status : Shows the status of the normal recorder currently connected to the standby recorder. To
delete the normal recorder connected, click <
Delete
> on the right side of the recorder.
■
The standby recorder can only enable some functions in the <
System
>, <
Device
>, and <
Network
> menus. You can't use the
<
Record
> and <
Event
> menus.
■
In the standby recorder, the previous operation will stop when a failover is performed during the playback or section export, and the screen
will move to the live screen.
State name
Description
Ready
Ready to be connected
Connected
Normal recorder and standby recorder connected (failover available)
Failover
Troubleshooting is being performed
Connected fail
Connection was attempted but failed
Authentication failure
Auth failed by entering an incorrect standby password when attempting to connect
Connected(Match Time Required)
Connected without time synchronization with the standby recorder
Connected(check camera port IP)
Even if the camera port of a normal recorder is connected to the viewer port of the standby
recorder or connected to the same viewer port, the IP port of the camera port is not matching.
Connected fail(check camera port IP)
The connection from the normal recorder's camera port to the standby recorder's camera port
failed.
Connected fail (It is a different model.)
Failed connection by connecting recorders of different models.
Example of setting up failover
– Subnet 1
➡
Network 1 (Camera)
– Subnet 2
➡
Network 2 (Viewer)
– Subnet 3
➡
Network 3 (iSCSI)
Subnet 1
Active
Active
Standby
Subnet 2
Recording Stream
Failover Monitoring
Fake Recording Stream