PROCEDURE
1
Flush the sample pipe.
1.1
Put an applicable container under the sample valve, refer to the paragraph
recommended procedure for samples in
.
1.2
Slowly open the sample valve to flush out oil and possible dirt.
1.3
Close the sample valve.
1.4
Discard the oil correctly.
2
Get an oil sample.
2.1
Put the sample bottle under the sample valve.
2.2
Slowly open the sample valve to fully fill the sample bottle.
NOTE:
The necessary quantity of oil is as follows:
•
100 ml for regular oil analysis
•
5 l for FZG and particle count analysis.
2.3
Close the sample valve.
2.4
Close the sample bottle tight.
3
Write the data that follows on the sample bottle:
•
Name of the ship
•
Type and serial number of the engine
•
Date of the sampling
•
Location of the sample point
•
Operating hours of the oil and of the engine
•
Brand and type of the oil.
4
again for the other sample point.
5
Send the sample bottles in an applicable package to a laboratory for analysis.
6
Do the procedures related to the results, refer to
CLOSE UP
•
None
X52
AA00-0000-00AAA-371B-A
Operation Manual
Do an analysis of the system oil
Winterthur Gas & Diesel Ltd.
- 331 -