VERSION 3
05/01/2021
I
NSTALLATION AND
U
SAGE
G
UIDE
WINESP40DUPRO
Page 6
1
GENERAL FEATURES
1.1
TECHNICAL SPECIFICATIONS
Outdoor unit
Indoor unit
Device dimensions, H x W x D
642 x 857 x 424 mm
317 x 638 x 546 mm
Weight of the device
55 kg
26 kg
Temperature setting
Preset to 12°C, adjustable from 8 to 18 °C
*
Max. outdoor temperature
40 °C
**
Cooling capacity
900 W at 15 °C
**
Electric power supply
230/240V-50 Hz
Electrical power in cooling mode
600 W
Electrical power in heating mode
500 W
Gas
R449
*
With insulation appropriate for the temperature and volume of the room.
**
As a result of power reduction depending on the outdoor temperature, the device may lose its capacity to maintain
12°C if the outdoor temperature approaches 40 °C.
The circuit breaker rating must be
16 Amperes.
If the thermal safety system trips too frequently, that may damage the compressor prematurely. In any
event,
steps must be taken to prevent the temperature of the discharge room being continually
near 40 °C
; that high temperature must be limited to the summer period at the most.
VENTILATED OR NO-FROST COOLING (schematic diagram)
EXTERIEUR
OUTDOOR
INTERIEUR de la cave
INDOOR, in the cellar
Air chaud
Hot air
détendeur
expansion valve
Ventilateur
Fan
CONDENSEUR
CONDENSER
COMPRESSEUR
COMPRESSOR
Ventilateur
Fan