Page 9
Front view
Side view
2
ARRANGEMENT
The air conditioner is made up of two separate units, a thermostat housing and a connections housing. They
must be connected to each other by rigid refrigeration piping and electrical connections.
The length of the refrigeration piping between the two units
may not exceed 20 m.
2.1
OUTDOOR UNIT
It may be placed outdoors or in an adjoining room.
If the unit is installed outdoors:
-
Place the unit so that the air intake and discharge are not impeded by any obstacles
-
Leave space above the unit (filter maintenance),
-
Select a clear location away from sunlight,
-
Raise the unit to avoid the build-up of water or snow,
-
Be mindful of noise and its effect on the neighbourhood.
If the unit is installed in a room:
-
Place the unit so that the air intake and discharge are not impeded by any obstacles,
-
Make sure the room is adequately ventilated,
-
Maximum non-permanent temperature in the room: 40 °C,
-
Recommended average temperature in the room: 20 °C.
2.2
INDOOR UNIT
The indoor unit must necessarily be installed inside the air-conditioned room.
2.3
THERMOSTAT HOUSING
The thermostat housing is installed either inside or outside the air-conditioned room.
For its part, the probe must always be placed in the air-conditioned room.
The supplied probe is 1.5 m long. It may be extended using insulated flexible cable with two conductors with
a minimum section of 0.5 mm².
2.4
CONNECTIONS HOUSING
The connections housing may also be installed inside or outside the air-conditioned room.
If the housing is installed outside the room, take account of the cable length (2 m).