3.2.2

 

AIR FLOW 

 

 

 

 

3.3

 

PUTTING IN PLACE THE INDOOR UNIT 

 
Because of the diversity of locations, each fitter must adapt to the constraints of the particular installation. 
 

Leave space for the refrigeration and electrical connections and the condensate drain pipe. 
The intake and discharge openings must not be obstructed, even in part. 

The discharge and intake must be separated in order to avoid taking back discharged air, even in 
part (as a test, the intake temperature must be identical to the temperature in the room when 
the device is cooling it). 

 

 
Make the electrical connections before fastening the indoor unit to the ceiling if permitted by the 
cable lengths (see section 3.6.2, p 19). 
 

 

3.3.1

 

INSTALLATION 

 

 

-

 

Use insulated ducts, 

Ø125mm 

 

-

 

Make sure you select the ideal location so that the duct length is 
as short as possible (14 m max in all/reduce by 1 m per number 
of bends) 

-

 

Bend radius ≥ 175

 mm 

-

 

Do not reduce the duct section 

 
 
Two finishing grilles are supplied with the device. They are adapted for the air flow of the air conditioner. 
 
 
 
 
 
 
 
 
 
 
 
 
 

INTAKE 

DISCHARGE 

Содержание WineSP40DUPRO

Страница 1: ...Instructions for installation and use Keep safe for future reference WineSP40DUPRO INFORMATION PROVIDED ON THE IDENTIFICATION PLATE OF THE DEVICE 1 Model 2 Serial no 3 Date of purchase 05 01 2021...

Страница 2: ...VERSION 3 05 01 2021 INSTALLATION AND USAGE GUIDE WINESP40DUPRO Page 2...

Страница 3: ...4 3 3 2 AIR FLOW 15 3 3 3 EXAMPLES OF ASSEMBLY OF THE INDOOR UNIT 15 3 4 PIPING CONNECTIONS 16 3 5 ADJUSTING THE EXPANSION VALVE 17 3 6 ELECTRICAL CONNECTIONS 18 3 6 1 CONNECTING THE OUTDOOR UNIT 18 3...

Страница 4: ...VERSION 3 05 01 2021 INSTALLATION AND USAGE GUIDE WINESP40DUPRO Page 4...

Страница 5: ...our satisfaction and we hope that it will enable you to store and mature your wine in the best possible way for peerless tasting pleasure Because we believe customer satisfaction is our primary goal w...

Страница 6: ...e and volume of the room As a result of power reduction depending on the outdoor temperature the device may lose its capacity to maintain 12 C if the outdoor temperature approaches 40 C The circuit br...

Страница 7: ...s Cool air Benefits of ventilated cooling No frost formation other than on the evaporator Automatic defrosting leading to maximum refrigeration efficiency More uniform cooling due to the continuous mo...

Страница 8: ...PRO Page 8 1 2 OVERALL DIMENSIONS Outdoor unit Distance minimale entre le mur et l unit ext rieure Minimum distance between wall and outdoor unit Indoor unit Front view Side view Thermostat housing Fr...

Страница 9: ...ul of noise and its effect on the neighbourhood If the unit is installed in a room Place the unit so that the air intake and discharge are not impeded by any obstacles Make sure the room is adequately...

Страница 10: ...ation The insulating materials should preferably be assembled By fitting the grooves of panels into each other or By gluing the panels to each other GOAL Avoiding the unwanted entry of heat and humidi...

Страница 11: ...ystyrene mm 0 030 W m 1 K 1 Thickness of polyurethane mm 0 025 W m 1 K 1 4 20 10 10 8 30 20 20 12 50 30 30 16 60 40 40 20 80 50 50 24 90 60 50 28 100 70 60 32 120 80 70 36 140 90 80 40 150 100 90 If g...

Страница 12: ...trong panel on the top Insulation lined with wood chipboard approximately 15 mm thick or any other appropriate covering e g screed and slab 2 6 2 DOOR It helps to keep the insulation continuous Two so...

Страница 13: ...nd 3 8 copper pipes for refrigeration connections Fasteners and tools for fastening the outdoor unit 3 2 PUTTING IN PLACE THE OUTDOOR UNIT 3 2 1 INSTALLATION Step 3 Fasten the brackets with the approp...

Страница 14: ...void taking back discharged air even in part as a test the intake temperature must be identical to the temperature in the room when the device is cooling it Make the electrical connections before fast...

Страница 15: ...021 INSTALLATION AND USAGE GUIDE WINESP40DUPRO Page 15 3 3 2 AIR FLOW 3 3 3 EXAMPLES OF ASSEMBLY OF THE INDOOR UNIT Installation on the air conditioned room Installation near the air conditioned room...

Страница 16: ...10 metres The number of bends per connection may not exceed 10 In order to have the right quantity of refrigerant in the device refer to the curve below for the refrigerant charge When satisfactory op...

Страница 17: ...screwdriver to give it the right number of turns for correct expansion valve adjustment Step 4 For R449 OPEN default adjustment the expansion valve by 2 TURNS turn the screwdriver anticlockwise FOR R...

Страница 18: ...it may only be replaced by the manufacturer its after sales department or a party with similar qualification 3 6 1 CONNECTING THE OUTDOOR UNIT Step 1 Unscrew and remove the electrical access plate of...

Страница 19: ...E WINESP40DUPRO Page 19 3 6 2 CONNECTING THE INDOOR UNIT Step 1 Unscrew and remove the front cover Step 2 Route the cord through the cable tie Step 3 Connect the cord as indicated in the wiring diagra...

Страница 20: ...O Page 20 3 6 3 POWER CONNECTION The connections housing must be connected to a single phase electricity line protected by a 230V 16A two pole circuit breaker 3 6 4 WIRING DIAGRAM PRESSURE ACTUATED SP...

Страница 21: ...ng of 12 C When the air conditioner is started up check and modify that temperature if required using procedure 4 2 1 p21 4 1 Connecting the air conditioner When you start the air conditioner the room...

Страница 22: ...n the display defrosting mode in progress Red indicator lit on the display heating mode engaged resistor 4 2 2 STANDBY MODE Putting the air conditioner on standby keep button 1 pressed in for 3 second...

Страница 23: ...as a washable reusable filter Unscrew the two plastic screws 1 Take off the filter cover 2 Take out the filter 3 Wash the filter with hot water Once the filter is clean and drained put it back in plac...

Страница 24: ...er fouled failure of the fan of the outdoor unit room in which the outdoor unit is located improperly ventilated presence of obstacles that impede the air flow etc If a safety system trips you only ne...

Страница 25: ...ly if the purchase invoice or a copy thereof can be produced 6 4 GUARANTEE EXCLUSIONS AND LIMITS The guarantee shall not apply in the following cases The insulation of the air conditioned room or inst...

Отзывы: