21
7.1
CHANGING THE FILTER
2
1
3
•
Unscrew the two plastic screws
1
•
Remove the cover
2
.
•
Pull the tab
3
to release the filter
Replace it with a WINEMASTER filter only !
You can then replace the cover
7.2
INFORMATION ABOUT AIRCONDITIONNER FUNCTIONNING
This airconditionner has a pressostat of high pressure security with manual
rearmament and a pressostat of low pressure security with automatic
rearmament.
The pressostat of high pressure protects the compressor in case of abnormal
rise of the pressure which can be due to several causes (obstruction,filter
clogged , breakdown of outside fan unit, local where is the outside unit badly
ventilated..)
In the case 1 and 2 , the simple rearmament of the device (having deleted the
cause) is sufficient. In all other cases, the technician intervention is necessary.
The low pressure security protects the compressor in case of some
dysfunctions (icing of the evaporator, bad exchange on the evaporator, too
low outside temperature in the starting phase) , breakdown of the fan on the
internal unit, the absence of coolant fluid consecutive to a leak.
However, as it is an automatic rearmament, in case the problem persists it is
better to stop the airconditionner until the technician intervention.