13
3
INSTALLATION OF THE INSIDE UNIT
-
Put the unit on the floor or on his horizontal support,
-
It
shouldn’t be any obstacle in front of the ventilation grid to facilitate the air flow
-
The support or floor must be level and not transmit vibrations.
-
3.1
RE-CONNECTION OF THE FLEXIBLE
Pass the connecting flexible through the hole in the wall and re-connect the refrigerant fittings with the wrenches
and the electrical connecting wires to the outside unit. The reconnection can be done to any pipe.
Attention : open the ends of the flexible connection when you pass them through the wall in order to keep
the end clean for screwing again.
3.2
INSTALLING THE CONDENSING WATER FLUE
1
2
3
•
Screw the plastic bend
1 supplied with the unit If necessary seal the threads with Teflon
•
Slide the PVC tubing
2
•
Screw up the ring clamp
3
•
Connect the free end of the PVC tubing to a wastewater point or a retention tank ( mini content 25 litres).
Avoid “counter slopes “ or « siphons »