20
The program of the thermostat from model WINEMASTER SP100 will run an automatic defrost time several times a
day. During this position, the compressor stops and only the fan in the cellar is functionning.
The condensate water produced during this period will b evacuated through the tube.
The thermostat display the
flashing message dF with room temperature.
6.5 MANUAL DEFROST
7
SERVICING THE WINEMASTER AIR-CONDITIONER
THE DUST FILTER
It is essential to replace the dust filter in the air-conditioner as soon as necessary and at least once a year. If it is
clogged, the air-conditioner could be seriously damaged.
-
The manual defrost is not necessary but
can be achieved by a 3 seconds
pressure on button 3. The compressor
stops
-
The thermostat shows «
dEF
» and
alternatively
the wine cellar
temperature
.
-
To come back, press again during 3
seconds on button 3.
-
The thermostat indicates «
ON
» during
1 second