• Set up copper connections
• Braze the connections to the fittings. ATTENTION RESPECT THE COLOR CODE ON YOUR MACHINE (blue
linked to blue, red linked to red) (2)
• Attention, cool the connections well during soldering
5.6
LOADING
The load of R407C must be 1 kg up to a maximum length of 8 meters then 48gr per meter. Do not exceed the
length of 15 meters.
The vacuum draw and the filling are done on the indoor unit.
6
USING THE WINEMASTER SP100
The Winemaster SP100 must be installed by complying with the national rules of electric
installation
6.1
CONNECTING THE AIR-CONDITIONER
Connect the male plug to a 230/16A power socket. Switch on the air-conditioner by pressing the green button on
the back of the inside unit..
The fan on the cellar side comes on immediately.
The compressor may not come on until 2 minutes later if the temperature in the cellar is higher than the set
temperature. If the cellar temperature matches the thermostat setting, the compressor will not come on.
6.2
CONTROL PANEL
The setting of the targeted temperature is made on the thermostat :