BATTERIES
QUICK 98560 09/20/99
4-9
TO REMOVE BATTERIES
FOR SAFETY: Before leaving or servicing
machine; Stop on level surface, set parking
brake, turn off machine and remove key.
1. Drain solution tank and raise the solution tank
and lock the support arm. Make sure the
support arm is fully engaged.
2. Disconnect battery pack from machine.
3. Use the proper size open end wrench to
disconnect main ground wire first and secure
cable terminal away from batteries.
4. Disconnect main positive lead and secure cable
terminal away from battery/batteries.
5. Loosen both terminals on each jumper cable
and remove one at a time.
6. Prepare a suitable site to place the batteries.
7. Attach suitable battery lifting device and lift
batteries from the machine.
Batteries are a potential environmental hazard.
Consult your battery supplier for safe disposal
methods.
FUSE LINK
(Refer to the “electrical Component Group”)
The fusible link protects the main contactors from
overload, and is located on electrical panel.
TO REPLACE FUSE LINK
FOR SAFETY: Before leaving or servicing
machine; Stop on level surface, set parking
brake, turn off machine and remove key.
FOR SAFETY: Disconnect all power to machine
by disconnecting battery pack from machine.
1. Remove plastic front cover from electrical panel.
2. Loosen nuts on burnt fuse.
3. Remove fuse by rotating and pulling up.
4. Replace
fuse.
5. Tighten
nuts.
6. Reinstall front cover.
!
WARNING