MACHINE OPERATION
FLX3 980087 04/01/03
3-15
!
WARNING
PRE-RUN MACHINE INSPECTION
Do a pre-run inspection to find possible problems
that could cause poor performance or lost time from
breakdown. Follow the same procedure each time to
avoid missing steps.
1.
Visually check for exterior damage, leaks,
damaged or worn tires.
2.
Check brushes or pads and drivers for proper
installation and wear. Weekly check scrub deck
skirts for proper contact with floor. See
BRUSHES in MAINTENANCE SECTION.
3.
Check debris hopper (cylindrical scrubhead) to
be sure it is empty.
4.
Check squeegee for wear and proper
adjustment. See SQUEEGEE ADJUSTMENT in
MAINTENANCE SECTION.
5.
Check for securely attached drain hose, plug,
and caps.
6.
Check battery condition, recharge if necessary.
See BATTERIES in maintenance section.
7.
Check the brakes and steering for proper
operation. See BRAKES and STEERING in
MAINTENANCE SECTION.
STARTING MACHINE
NOTE:
Perform pre-run machine check before
operating machine.
FOR SAFETY:
Before starting machine, make
sure that all safety devices are in place and
operating properly.
1.
The operator should be in the seat with foot on
the brake pedal or with the parking brake on.
The directional pedal must be in the neutral
position to avoid unintentional movement.
NOTE:
The Operator must be in position on the
seat to activate machine in desired direction.
2.
Turn the key switch clockwise to the “ON”
position.
3.
Release the brake, then press lightly on the
directional pedal in the desired direction and
drive to the filling area.
FILLING THE MACHINE
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, set parking
brake, turn off machine and remove key.
1.
Set squeegee and scrub deck to up position, set
parking brake, and turn off key switch.
2.
Remove solution tank cover.
Flammable materials can cause an explosion or
fire. Do not use flammable materials in the tanks.
3.
The solution tank can be filled to the bottom lip
of the fill inlet. Leave room for detergent. The
solution tank capacity is 50 gallons (189 liters).
The water must not be hotter than 140
L
(60
L
C) to
prevent damage to the tank. Measure the
required amount of chemical into the solution
tank after filling with water. Dry chemicals
should be thoroughly mixed before being added
into solution tank. Commercially available, high
alkaline floor cleaners are suitable for use in the
solution system.
4.
Inspect solution tank cover vent for obstructions.
Replace solution tank cover.