58
4.
For the Service Technician
BioWIN XL
BWE 350 NA
BWE 450 NA
BWE 600 NA
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Factory setting:
rpm
750
2100
1100
2600
1050
2700
Setting range:
rpm
750–950
2000–2400
1000–1300
2600–2700
950–1250
2600–2700
Minimum operating time with buffer
This function is not yet available.
Correction of cleaning interval
The cleaning interval is dependent both on the ash removal profile, and on the
proportion of ash in the pellets. This setting can be used to extend or shorten
the cleaning interv
al by ±50 %.
The standard setting is a cleaning interval determined by testing.
Factory setting:
0 %
Setting range:
±50 %
Fig. 133
Correction of Cleaning interval
Actual value
0 %
min.
-50 %
max.
+50 %
–
save
back
+
Flue gas thermostat or air intake/exhaust flap
This setting can be used to change the flue gas thermostat function (factory
setting) to the air intake/exhaust flap function.
Factory setting:
Flue gas thermostat
With air intake/exhaust flap setting (Fig. 135):
Factory setting:
Operating time 300 sec.
Setting range:
30 – 600 sec.
Fig. 134
Flue gas thermostat or Air intake
flap
Flue gas thermostat
Air intake/exh. flap
choose
back
Fig. 135
Air intake/exh. flap
Operating time
300 sec.
min.
30 sec.
max.
600 sec.
–
save
back
+
Limits for blower speed
Fig. 136
Limits for blower speed
Minimum
1100 rpm
Maximum
2600 rpm
choose
back
Fig. 137
Minimum operating time
with buffer
Actual value
60 min.
min
0 min.
max
180 min.
–
save
back
+
CAUTION
If too long of a cleaning interval is selected, the
ash container may overfill.
INFORMATION
The set operating time should be twice as long
as the actual operating time of the air intake/
exhaust flap.