56
4.
For the Service Technician
BioWIN XL
BWE 350 NA / BWE 450 NA / BWE 600 NA
Actual value
Factory setting:
Setting range:
61.7 lbs/hr / 28 kg/h
±11 lbs / 5 kg of range
Range
Factory setting:
Setting range:
61.7 lbs/hr / 28 kg/h
48.5-79.4 lbs/hr (22–36 kg/h)
Correction
Factory setting:
Setting range:
0
± 11 lbs / 5 kg
Delivery time ignition phase
Fuel quantity in the ignition phase.
BioWIN XL
BWE 350 NA
BWE 450 NA
BWE 600 NA
Factory setting:
240 s
280 s
210 s
Setting range:
190 – 290 s
230 – 330 s
160 – 260 s
Hysteresis Burner ON
Switching hysteresis for burner control.
Factory setting:
5 K
Setting range:
0 – 20 K
4.4.1 Parameters
Use the
arrow
buttons to select the following parameters. Use the
choose
button to confirm the choice.
– Number of burner starts
– Fuel quantity auger conveyor
– Delivery time ignition phase
– Hysteresis Burner ON
– Maximum value of set temperature
– Set temperature ext. heating requirement
– Type of pellet feed system
– Operating time of suction turbine
– Profile ash removal
– Correction of cleaning interval
– Flue gas thermostat or air intake/exhaust flap
– Limits for blower speed
– Minimum operating time with buffer
Number of burner starts
The BioWIN XL‘s number of burner starts is displayed.
Fig. 123
Number of burner starts
1.350
back
Fig. 124
Fuel quantity
Auger conveyor
Actual value
55 lbs
Range
61.7 lbs
Correction
0
choose
back
Fuel quantity auger conveyor
The calculated fuel quantity (actual value) and the range are displayed in lbs/h
or kg/h, and can be adjusted.
Fig. 125
Delivery time ignition phase
Actual value
240 s
min.
190 s
max.
290 s
–
save
back
+
Fig. 126
Hysteresis Burner ON
Actual value
5 K
min.
0 K
max.
20 K
–
save
back
+