57
4.
For the Service Technician
Fig. 127
Maximum value of set
temperature
Actual value
167°F
min.
140 °F
max.
185 °F
–
save
back
+
Maximum value of set temperature
This is the maximum setpoint achievable in normal heating operation.
Factory setting:
167 °F / 75 °C
Setting range:
140 – 185 °F / 60 – 85 °C
Fig. 128
Set temperature ext.
heating requirement
Actual value
158°F
min.
95 °F
max.
185 °F
–
save
back
+
Set temperature ext. heating requirement
This is the set temperature for external heating requirement.
Factory setting:
158 °F / 70 °C
Setting range:
95 – 185 °F / 35 – 85 °C
This setting is not available in North America.
Type of pellet feed system
Setting for if the operation is without a feed system, with 2 to 8 probes, or with
a mixer (buried tank).
Factory setting: Without feed system
The following settings are available:
USA/Canada
For changeover unit with 3 probes: Suction turbine with 2 probes
Suction turbine with 3 probes
Europe only:
For changeover unit with 8 probes: Suction turbine with 4 probes
Suction turbine with 6 probes
Suction turbine with 8 probes
For buried tank with mixer
Suction turbine with mixer
Fig. 129
Type of pellet feed system
without feed system
Suction turbine
with 2 probe
Suction turbine with 3 probe
Suction turbine with 4 probe
Suction turbine with 6 probe
choose
back
Fig. 130
Type of pellet feed system
Suction turbine with 8 probe
Suction turbine with mixer
choose
back
Operating time of suction turbine
Factory setting:
120 sec.
Setting range:
90 – 240 sec.
Fig. 131
Operating time of
suction turbine
Actual value
120 sec.
min.
90 sec.
max.
240 sec.
–
save
back
+
Profile ash removal
This setting can be used to adjust the removal of ash from the burner pot for
different levels of pellet quality.
Factory setting: Stage 1
Stage 0
to
Stage 3
very low proportion of ash
very high proportion of ash
(possibly formation of slag)
INFORMATION
Restore factory settings for each delivery of
pellets.
Fig. 132
Profile ash removal
Stage 0
Stage 1
Stage 2
Stage 3
save
back