28
2.
For the Installer
– Remove cladding door cover (part 6) from cladding door; remove 4 self-tapping screws (Fig. 56), push cover
back and lift – Fig. 57.
Fig. 56 Demounting cladding door cover –
removing screws
Fig. 57 Removing cladding door cover
– Thread InfoWIN
PLUS
cable into door – Fig. 60.
– Mount InfoWIN
PLUS
(part 8) on cladding door cover (part 6) with a saw tooth ring for grounding (Fig. 61) and
3 nuts – Fig. 62.
Fig. 58 Fitting both hinges on cladding door
Fig. 59 Mounting cladding door with
hinges on right side panel
Fig. 60 Threading InfoWIN
PLUS
cable into
door
Fig. 61 Fit saw tooth ring under one nut –
grounding
– Fit both door hinges (part 5) top and bottom in cladding door (part 9) with 2 countersunk screws each – Fig. 58.
– Mount cladding door (part 9) with hinges on right side panel (part 4) using 2 countersunk screws, and insert
InfoWIN
PLUS
cable through opening – Fig. 59.
2x
M4 x 16
2x
M4 x 16
1x