W83627DHG
Publication Release Date: Aug, 22, 2007
-70- Version
1.4
8.25 AUXFANOUT Start-up Value Register - Index 16h (Bank 0)
Register Location:
16h
Power on Default Value: 01h
Attribute: Read/Write
Size: 8
bits
7 6 5 4 3 2 1 0
AUXFANOUT Start-up Value
In Thermal Cruise
TM
mode, the AUXFANOUT value increases from zero to this eight-bit register value
to provide a minimum value to turn on the fan.
8.26 AUXFANOUT Stop Time Register - Index 17h (Bank 0)
Register Location:
17h
Power on Default Value: 3Ch
Attribute: Read/Write
Size: 8
bits
7 6 5 4 3 2 1 0
AUXFANOUT Stop Time
In Thermal Cruise
TM
mode, if the stop value is enabled, this register determines the amount of time it
takes the AUXFANOUT value to fall from the stop value to zero.
(1) For PWM output,
The units are intervals of 0.1 second. The default time is 6 seconds.
(2) For DC output,
The units are intervals of 0.4 second. The default time is 24 seconds.