8.17 Fan Output Step Down Time Register - Index 0Eh (Bank 0)
Register Location:
0Eh
Power on Default Value: 0Ah
Attribute: Read/Write
Size: 8
bits
7 6 5 4 3 2 1 0
FANOUT Value Step Down Time
In S
MART
F
AN
TM
mode, this register determines the amount of time it takes FANOUT to decrease its
value by one step.
(1)For PWM output:
The units are intervals of 0.1 seconds. The default time is 1 seconds.
(2)For DC output:
The units are intervals of 0.4 seconds. The default time is 4 seconds.
8.18 Fan Output Step Up Time Register - Index 0Fh (Bank 0)
Register Location:
0Fh
Power on Default Value: 0Ah
Attribute: Read/Write
Size: 8
bits
7 6 5 4 3 2 1 0
FANOUT Value Step Up Time
In S
MART
F
AN
TM
mode, this register determines the amount of time it takes FANOUT to increase its
value by one step.
(1)For PWM output:
The units are intervals of 0.1 second. The default time is 1 second.
(2)For DC output:
The units are intervals of 0.4 second. The default time is 4 seconds.