W83627DHG
Publication Release Date: Aug, 22, 2007
-105- Version
1.4
Bit 4: SYSTIN temperature sensor status.
1: Temperature exceeds the over-temperature value.
0: Temperature is under the hysteresis value.
Bit 3: 3VCC Voltage status.
1: 3VCC voltage is over or under the allowed range.
0: 3VCC voltage is in the allowed range.
Bit 2: AVCC Voltage status.
1: AVCC voltage is over or under the allowed range.
0: AVCC voltage is in the allowed range.
Bit 1: VIN0 Voltage status.
1: VIN0 voltage is over or under the allowed range.
0: VIN0 voltage is in the allowed range.
Bit 0: CPUVCORE Voltage status.
1: CPUVCORE voltage is over or under the allowed range.
0: CPUVCORE voltage is in the allowed range.
8.93 Real Time Hardware Status Register II - Index 5Ah (Bank 4)
Register Location:
5Ah
Power on Default Value: 00h
Attribute: Read
Only
Size: 8
bits
7 6 5 4 3 2 1 0
VIN1_STS
TAR4_STS
CPUFANIN1_STS
AUXFANIN0_STS
CASEOPEN_STS
AUXTIN_STS
TAR1_STS
TAR2_STS
Bit 7: Smart Fan of CPUFANIN0 warning status.
1: Selected temperature has been over the target temperature for three minutes at full fan speed
in Thermal Cruise
TM
mode.
0: Selected temperature has not reached the warning range.
Bit 6: Smart Fan of SYSFANIN warning status.
1: SYSTIN temperature has been over the target temperature for three minutes at full fan speed
in Thermal Cruise
TM
mode.
0: SYSTIN temperature has not reached the warning range.
Bit 5: AUXTIN temperature sensor status.
1: Temperature exceeds the over-temperature value.
0: Temperature is under the hysteresis value.