W83627DHG
Publication Release Date: Aug, 22, 2007
-93- Version
1.4
8.66 SYSFANOUT Critical Temperature register - Index 6Bh (Bank 0)
Register Location:
6Bh
Power on Default Value:
FFh
Attribute: Read/Write
Size: 8
bits
In Thermal Cruise
TM
mode, when the function of SYSFANOUT temperature sensing is enabled, and the
monitored temperature exceeds the threshold temperature, the SYSFANOUT will work at full speed.
8.67 CPUFANOUT0 Critical Temperature Register - Index 6Ch (Bank 0)
Register Location:
6Ch
Power on Default Value:
FFh
Attribute: Read/Write
Size: 8
bits
In Thermal Cruise
TM
mode, when the function of CPUFANOUT0 temperature sensing is enabled, and
the monitored temperature exceeds the threshold temperature, the CPUFANOUT0 will work at full
speed.
8.68 AUXFANOUT Critical Temperature Register - Index 6Dh (Bank 0)
Register Location:
6Dh
Power on Default Value:
FFh
Attribute: Read/Write
Size: 8
bits
7 6 5 4 3 2 1 0
CPUFANOUT0 Critical temperature
7 6 5 4 3 2 1 0
SYSFANOUT Threshold temperature