en
Installation and operating instructions • Wilo-Flumen OPTI-TR 50-3 ... 120-1, Wilo-Flumen EXCEL-TRE 50-3 ... 90-2 • Ed.01/2022-07
11
Fig. 1:
Attachment point
•
Wear protective equipment! Observe the work regulations.
–
Protective gloves: 4X42C (uvex C500 wet)
–
Safety shoes: Protection class S1 (uvex 1 sport S1)
•
Attach the mixer to the attachment point.
•
Protect the connection cable against water ingress.
•
Only remove the outer packaging at the site of use to ensure that the mixer is not dam-
aged during transport.
•
Use tear-proof plastic sacks of sufficient size to package used mixers for transport in a
leak-proof manner.
3.3
Use of lifting equipment
If lifting equipment (lifting device, crane, chain hoist …) is used, observe the following
points:
•
Wear a safety helmet according to EN 397!
•
Comply with local regulations on the use of lifting equipment.
•
The technically correct use of the lifting equipment is the operator’s responsibility!
•
Lifting gear
–
Use legally specified and approved lifting gear.
–
Select lifting gear based on the attachment point.
–
Attach lifting gear to the attachment point according to local regulations.
•
Lifting equipment
–
Check for proper function before use!
Only use properly functioning lifting equipment!
–
Sufficient bearing capacity.
–
Ensure stability during use.
•
Lifting operation
–
Do not jam the product when lifting and lowering it.
–
Do not exceed the max. permissible bearing capacity!
–
If necessary (e.g. blocked view), assign a second person to coordinate.
–
No one should stand under suspended loads!
–
Do not move loads over workplaces where persons are present!
3.4
Storage
DANGER
Danger due to fluids which are hazardous to health!
Danger of bacterial infection!
• Disinfect the mixer after removal.
• Observe the specifications of the work regulations.
WARNING
Risk of injury from sharp edges!
Sharp edges can form on the propeller blades. There is a danger of cuts
and similar injuries!
• Wear protective gloves!
CAUTION
Total damage from to moisture ingress
Moisture ingress in the connection cable damages the connection cable
and the mixer! Never immerse the end of the connection cable in a fluid
and firmly seal it during storage.