10.2 Technical data
General data
Temperature detection:
Measurement range
/ °C
Accuracy
/ K
0 to +45
± 0.5
1)
Housing colour
RAL 9016
Dimensions W x H x D
/ mm
91 x 89 x 29
Weight/ kg
0.2
Permitted field of application
Permitted ambient temperature
/
°C
0 to +60
Storage temperature
/ °C
-20 to +65
Relative humidity
/ %
0 to 95% (non-condensing)
Electrical connection/
power supply
Mains connection /V DC SELV
24 (min. 15/max. 26.4)
Max. current consumption/mA
< 30
2)
Connection system
WAGO terminals type 243-211 red/dark grey
Stripping length /mm
5 to 6
Geniax BUS
BUS termination resistance/
Ω
120
3)
Connection system
WAGO terminals type 243-212 yellow/light grey
Stripping length /mm
5 to 6
Electronics
Electromagnetic compatibility
EN 55022
Emitted interference
EN 61000-6-3
Interference resistance
EN 61000-6-2
Protection class
IP 20/II
Materials
Housing
Lower part of housing: Plastic PC
Housing, upper part: Plastic PMMA/PC
1) In the range of +15 to +25°C
2) Device active, display lighting switched on
3) Can be activated/deactivated via the termination switch (DIP switch) at the Basic Control