EG - Konformitätserklärung 

 

 

GB 

EC – Declaration of conformity 

 

 

Déclaration de conformité CE 

 

(gemäß 2004/108/EG Anhang IV,2 und 2006/95/EG Anhang III,B,  

according 2004/108/EC annex IV,2 and 2006/95/EC annex III,B, 

conforme 2004/108/CE appendice IV,2 et 2006/95/CE appendice III B)

 

 
 

Hiermit erklären wir, dass die Bauarten der Baureihe : 

Geniax Central Control 

Herewith, we declare that this product: 

Geniax Central Control black

 

Par le présent, nous déclarons que cet agrégat : 

Geniax Comfort Control

 

 

Geniax Comfort Control black

 

 

Geniax Basic Control 

 

Geniax Basic Control black 

 

Geniax Ambient Sensor 

 

in der gelieferten Ausführung folgenden einschlägigen Bestimmungen entspricht: 

 

in its delivered state complies with the following relevant provisions: 

 

est conforme aux dispositions suivants dont il relève: 

 

 

Elektromagnetische Verträglichkeit - Richtlinie 

2004/108/EG 

 

Electromagnetic compatibility - directive 

 

Compatibilité électromagnétique- directive 

 

 

 

Niederspannungsrichtlinie 2006/95/EG 

 

Low voltage directive 

 

Directive basse-tension 

 

 

 

und entsprechender nationaler Gesetzgebung. 

 

 

and with the relevant national legislation. 

 

 

et aux législations nationales les transposant. 

 

 

 

Angewendete harmonisierte Normen, insbesondere: 

EN 60335-2-51 

 

Applied harmonized standards, in particular: 

EN 55014-1 

 

Normes harmonisées, notamment: 

EN 61000-6-2

 

 

 

EN 61000-6-3 

 

 

Bei einer mit uns nicht abgestimmten technischen Änderung der oben genannten Bauarten, verliert diese Erklärung ihre Gültigkeit. 
If the above mentioned series are technically modified without our approval, this declaration shall no longer be applicable. 
Si les gammes mentionnées ci-dessus sont modifiées sans notre approbation, cette déclaration perdra sa validité. 

 

Dortmund, 06.04.2011 

 

 

 
 
 
 

 

 

 

Erwin Prieß 

Quality Manager 

 
 

 

 
WILO SE 
Nortkirchenstraße 100 
44263 Dortmund 
Germany 

Document: 2109714.2 

Содержание Drain-TM

Страница 1: ...21 5 C GB User manual www geniax de Wilo Drain TM 2 122 586 Ed 01 2011 04 Wilo...

Страница 2: ......

Страница 3: ...ion button 6 3 2 2 Operational readiness 6 4 How does the temperature control work 7 5 Operation 9 6 Explanation of symbols 10 6 1 Regular system status 10 6 2 System status due to maintenance fault 1...

Страница 4: ...ons for future use Symbols used The following symbols are used in these instructions to designate notes Use of highlighting In these instructions the following types of highlighting are used to design...

Страница 5: ...ting concept of the Basic Control is described in the section 3 2 Operating concept page 6 Here you will find out to operate the Basic Control Operation The function of the Basic Control is described...

Страница 6: ...ised Pump System Any other utilisation or any utilisation that exceeds this is not considered to be an intended use Intended use also includes adherence to these operating instructions Warning This d...

Страница 7: ...sic Control 5 Overview of the Basic Control English 3 Overview of the Basic Control Fig 1 Basic Control Fig 2 Display elements display Display page 6 Navigation button page 6 System status page 6 Room...

Страница 8: ...ure which is currently being maintained in the room 3 2 Operating concept The Basic Control is operated using the navigation button 3 2 1 Navigation button The navigation button can be actuated in two...

Страница 9: ...during which the room is heated up or kept at a lower temperature Fig 3 Representation of the heating sequence during a day in accordance with the specifica tions from the Geniax Central Control time...

Страница 10: ...uence will again follow the preset time profile Fig 4 Representation of the heating sequence during a day in accordance with the specifications from the Geniax Central Control time profile with three...

Страница 11: ...om target temperature with the and buttons for a higher temperature for a lower temperature The display shows the changed room target tempera ture The symbol indicates the Intervention sys tem status...

Страница 12: ...ted in accord ance with the time profile as set by the customer in a Geniax Central Control Manual intervention The normal operation is currently being overrid den by the user Until the end of the tim...

Страница 13: ...ct prevents damage to the environment and risks to personal health 1 Use public or private disposal organisations when dis posing of all or part of the product 2 For more information on proper disposa...

Страница 14: ...ns an increase in heating costs of up to 6 Also adapt the setting of the room temperature to the corresponding use of the room It is normally not neces sary to continuously heat rooms that are seldom...

Страница 15: ...uncontrolled warmth transfer via enclosing surfaces that is walls doors ceilings floors to unheated neighbouring rooms Heating energy is inadvertently lost This can lead to the performance of the rad...

Страница 16: ...greater heating loss by glass and frames of windows and doors Additional savings can therefore be achieved by roller blinds folding shutters and also by curtains and blinds The energy savings which c...

Страница 17: ...30 2 Connection system WAGO terminals type 243 211 red dark grey Stripping length mm 5 to 6 Geniax BUS BUS termination resistance 120 3 Connection system WAGO terminals type 243 212 yellow light grey...

Страница 18: ...agnetische Vertr glichkeit Richtlinie 2004 108 EG Electromagnetic compatibility directive Compatibilit lectromagn tique directive Niederspannungsrichtlinie 2006 95 EG Low voltage directive Directive b...

Страница 19: ...ny wyr b jest zgodny z nast puj cymi dokumentami Sm rnice o elektromagnetick kompatibilit 2004 108 ES dyrektyw dot kompatybilno ci elektromagnetycznej 2004 108 WE 2004 108 EG Sm rnice pro n zk nap t 2...

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ...9500 wilo wilo hu India WILO India Mather and Platt Pumps Ltd Pune 411019 T 91 20 27442100 service pun matherplatt co in Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 citrawilo...

Страница 24: ...e Bau Bergbau Industrie WILO SE Nortkirchenstra e 100 44263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 kundendienst wilo com T glich 7 18 Uhr erreich bar 24 Stunden Tec...

Отзывы: