background image

English

Explanation of symbols

10

WILO SE 04/2011

6

Explanation of symbols

All system status symbols which can appear in the display 
are listed below. 

7

Maintenance

Only use a damp cloth to clean your Geniax Basic Control 
(as well as the electronics cover, unit casings, design cas-
ings).

Do not use soap, washing-up liquid, scouring powder or 
caustic cleaning agent which could damage the housing 
material.

6.1 Regular system status

Symbol

Meaning

Brief explanation

Time profile 
(normal operation)

Normal operation: The room is heated in accord-
ance with the time profile as set by the customer 
in a Geniax Central Control.

Manual intervention

The normal operation is currently being overrid-
den by the user. Until the end of the time area 
stored in the time profile, the room will be heated 
up to the selected room target temperature.

Summer operation

The heating of the room is switched off due to a 
high outdoor temperature. Summer operation is 
automatically ended by the Geniax Server as 
soon as the outside temperature drops again.

6.2 System status due to maintenance/fault

Symbol

Meaning

Brief explanation

Fault/warning

A fault in the Geniax System or in the Basic Con-
trol has occurred. The system/room user inter-
face has to be checked by a technician.

Содержание Drain-TM

Страница 1: ...21 5 C GB User manual www geniax de Wilo Drain TM 2 122 586 Ed 01 2011 04 Wilo...

Страница 2: ......

Страница 3: ...ion button 6 3 2 2 Operational readiness 6 4 How does the temperature control work 7 5 Operation 9 6 Explanation of symbols 10 6 1 Regular system status 10 6 2 System status due to maintenance fault 1...

Страница 4: ...ons for future use Symbols used The following symbols are used in these instructions to designate notes Use of highlighting In these instructions the following types of highlighting are used to design...

Страница 5: ...ting concept of the Basic Control is described in the section 3 2 Operating concept page 6 Here you will find out to operate the Basic Control Operation The function of the Basic Control is described...

Страница 6: ...ised Pump System Any other utilisation or any utilisation that exceeds this is not considered to be an intended use Intended use also includes adherence to these operating instructions Warning This d...

Страница 7: ...sic Control 5 Overview of the Basic Control English 3 Overview of the Basic Control Fig 1 Basic Control Fig 2 Display elements display Display page 6 Navigation button page 6 System status page 6 Room...

Страница 8: ...ure which is currently being maintained in the room 3 2 Operating concept The Basic Control is operated using the navigation button 3 2 1 Navigation button The navigation button can be actuated in two...

Страница 9: ...during which the room is heated up or kept at a lower temperature Fig 3 Representation of the heating sequence during a day in accordance with the specifica tions from the Geniax Central Control time...

Страница 10: ...uence will again follow the preset time profile Fig 4 Representation of the heating sequence during a day in accordance with the specifications from the Geniax Central Control time profile with three...

Страница 11: ...om target temperature with the and buttons for a higher temperature for a lower temperature The display shows the changed room target tempera ture The symbol indicates the Intervention sys tem status...

Страница 12: ...ted in accord ance with the time profile as set by the customer in a Geniax Central Control Manual intervention The normal operation is currently being overrid den by the user Until the end of the tim...

Страница 13: ...ct prevents damage to the environment and risks to personal health 1 Use public or private disposal organisations when dis posing of all or part of the product 2 For more information on proper disposa...

Страница 14: ...ns an increase in heating costs of up to 6 Also adapt the setting of the room temperature to the corresponding use of the room It is normally not neces sary to continuously heat rooms that are seldom...

Страница 15: ...uncontrolled warmth transfer via enclosing surfaces that is walls doors ceilings floors to unheated neighbouring rooms Heating energy is inadvertently lost This can lead to the performance of the rad...

Страница 16: ...greater heating loss by glass and frames of windows and doors Additional savings can therefore be achieved by roller blinds folding shutters and also by curtains and blinds The energy savings which c...

Страница 17: ...30 2 Connection system WAGO terminals type 243 211 red dark grey Stripping length mm 5 to 6 Geniax BUS BUS termination resistance 120 3 Connection system WAGO terminals type 243 212 yellow light grey...

Страница 18: ...agnetische Vertr glichkeit Richtlinie 2004 108 EG Electromagnetic compatibility directive Compatibilit lectromagn tique directive Niederspannungsrichtlinie 2006 95 EG Low voltage directive Directive b...

Страница 19: ...ny wyr b jest zgodny z nast puj cymi dokumentami Sm rnice o elektromagnetick kompatibilit 2004 108 ES dyrektyw dot kompatybilno ci elektromagnetycznej 2004 108 WE 2004 108 EG Sm rnice pro n zk nap t 2...

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ...9500 wilo wilo hu India WILO India Mather and Platt Pumps Ltd Pune 411019 T 91 20 27442100 service pun matherplatt co in Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 citrawilo...

Страница 24: ...e Bau Bergbau Industrie WILO SE Nortkirchenstra e 100 44263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 kundendienst wilo com T glich 7 18 Uhr erreich bar 24 Stunden Tec...

Отзывы: