21759-6-0608
Page 35
Installing Vent Components (Figure 56)
Begin the vent system installation by installing the first Simpson Duravent
component, 90° elbow to the starting collars or straight pipe on the top of
the appliance, then the straight pipe length and then horizontal or vertical
termination kit.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The inner
flue joints do not require any sealant.
Simpson Duravent vent system components lock into place by sliding the
concentric pipe section with four (4) equally spaced interior beads onto
the appliance collar or previously installed component end with four (4)
equally spaced indented sections. When the internal beads of each starting
outer pipe line up, rotate pipe section clockwise 90° (approximately 3
inches). The vent pipe is now locked together.
Continue adding components per the pre-planned vent system configuration.
Be certain that each succeeding vent component is securely fitted and
locked into the preceding component in the vent system.
WALL THIMBLE
(MAXIMUM OF
THREE 90 ELBOWS)
(MAXIMUM OF
TWO 90 ELBOWS)
VENT SYSTEM IDENTIFICATION
Figure 56
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers
and pricing.
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers.
DVVK-4VP
(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical, Includes SD-991, SD-953, and
SD-943
DVVK-4RE Direct-Vent Fireplace Vent Kit, Thru-the-wall, for 5 to 13 3/4 inch wall
thickness
DVVK-4TP
(DVVK-4T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to 11 inch
wall thickness, Includes SD-911, SD-985, SD-990 and SD-942
DVVK-4TSP
(DVVK-4TS)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to 7 inch
wall thickness, Includes SD908, SD-985, SD-990 and SD-942
DVVK-4FV Direct-Vent Fireplace Vertical Flex Vent Kit
DVA47
Top Vented Adaptor - For use with above vent kits
Содержание DVP42FP
Страница 48: ...21759 6 0608 Page 48 Figure 82 OPTIONAL THERMOSTAT OPTIONAL WALL SWITCH STANDING PILOT WIRING DIAGRAM ...
Страница 56: ...21759 6 0608 Page 56 INTERMITTENT PILOT TROUBLESHOOTING continued ...
Страница 60: ...21759 6 0608 Page 60 WIRING DIAGRAM WITH BLOWER Figure 85 RF WIRING DIAGRAM ...
Страница 71: ...21759 6 0608 Page 71 SERVICE NOTES ...