15
CHAPTER VI
CHART # 1
NEW REGULATION WITH FLOWMOTOR CONTROL
Adjustment too high
Thermostat
Element
Bent
Binding in stuffing box
Flow motor
Worn lap fit on fuel valve stem
Fuel stem not screwed into piston rod sufficiently
Packing glands too tight
Piston binding
Weak, short or broken spring
Vaporizer nozzle too large
Water Regulator
Dirty screen
Insufficient lift of pin valve
Checks
Flow motor check leaking Hand pump checks leaking
O
V
E
R
H
E
A
T
IN
G
Water Cushion
Sprig broken - Piston Binding
Adjustment too low
Thermostat
Water valve
Weak spring
Short spring
Tight stuffing box
Seat leaking
Seat out of alignment
Flowmotor
Piston binding
Water passing piston.
Nozzle tip clogged
Carbonized vaporizer
Choked supply
Dirty strainer
Valves not open enough
Vaporizer nozzle too small
W
E
T
S
T
E
A
M
Fuel ratio
20 HP fuel valve on 30 HP car
Water leak on feed line
Leaking flowmotor bypass valve
Leaking water regulator
Rough pin or seat
Pin wedging
Screen wedging
Clogged Generator
Suction line
Porous hose
Flabby hose
Dirty strainer
Cracked diaphragm
Insufficient throttle opening
Leaky stuffing boxes
N
O
P
O
W
E
R
Dry Steam
Pumps
Faulty checks
(Pitted balls
(Flat balls
(Loose seals
(Too much lift
Thermo valve
Weak spring
Tight packing
Needle binding on seat
Boiler check leaking
Speed constant
Thermo element
Slightly bent
Tight stuffing box
V
A
R
Y
IN
G
H
E
A
T
Speed varying
Flow motor adjustment
Leaky thermo valve.
Thermo valve loose (lock nut)
Dirty generator