MOUNTING THE EVAPORATOR UNIT
NOTE:
You are
REQUIRED
to use only the mounting locations provided
.
These locations
ensure that the installer will not drill into any copper or electrical wiring within the system.
3.
Secure the mounting bracket to the unit using the twelve (12) supplied 3/8”
s Philips
pan-head screws
.
4
.
Unscrew the
eighteen
(
18
) screws and remove the
top and electrical access panels.
TOP PANEL
ELECTRICAL
ACCESS
PANEL
Figure 1
5
.
Remove the knockout(s) that you will be using to route
the line set, power wires, display cable, bottle probe, and drain
line. For ease of installation, see Figure 2 for recommended orientation (with attic access).
Figure 2
Page 13